Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The purpose of this study was to investigate the effect of fatigue status and contraction type on complexity of the surface electromyographic (sEMG) signal. Twelve females (mean age ± SD = 21.1 ± 1.4 years) performed three fatigue-inducing protocols that involved maximal concentric, eccentric, or isometric knee-extensor contractions over three non-consecutive sessions. Pre- and post-fatigue assessments were also completed each session and consisted of three maximal efforts for each type of contraction. Complexity of sEMG signals from the vastus lateralis was assessed using Sample Entropy (SampEn) and Detrended Fluctuation Analysis (DFA) as expressed using the scaling exponent α. The results showed that fatigue decreased ( < 0.05) sEMG complexity as indicated by decreased SampEn (non-fatigued: 1.57 ± 0.22 > fatigued: 1.46 ± 0.25) and increased DFA α (non-fatigued: 1.27 ± 0.26 < fatigued: 1.32 ± 0.23). In addition, sEMG complexity was different among contraction types as indicated by SampEn (concentric: 1.58 ± 0.22 > eccentric: 1.47 ± 0.27 and isometric: 1.50 ± 0.21) and DFA α (concentric: 1.27 ± 0.18 < isometric: 1.32 ± 0.18). Thus, these findings suggested sEMG complexity is affected by fatigue status and contraction type, with the degree of fatigue-mediated loss of complexity dependent on the type of contraction used to elicit fatigue.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6524352 | PMC |
http://dx.doi.org/10.3390/sports7040078 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!