A new approach to estimate normal and tangential contact parameters in the foot-ground contact during human gait was proposed. A correct estimation of the contact parameters would be very important in the resolution of predictive forward dynamic problems. The normal contact forces have been well estimated in the literature. But accurate estimation of tangential forces has not been reached yet. This work proposed a new procedure to accurately estimate friction forces. The approach has been based on the consideration of the modulus of the tangential force instead of its components. This modulus was introduced together with the modulus of the normal contact force and its two associated moments in an optimization algorithm to fit the contact forces provided by the model to the experimental data obtained with a force plate. An inverse dynamics problem was solved as a step previous to the optimization algorithm. The results showed that both the normal and tangential forces and the moments in the horizontal plane were in agreement with the experimental measurements. This work also analyzed the influence on the results of the friction law. The results obtained with the general friction law, which considered dry (static and dynamic) and viscous friction, were compared with results provided by simpler laws. The analysis of the components of the friction forces pointed out the importance of the Stribeck component in the resultant force instead of the viscous friction which played a minimal role. But for modelling the stick-slip transition, the implementation of a general friction law is necessary.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/10255842.2019.1599363 | DOI Listing |
Sci Rep
December 2024
School of Mechanical Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan, 250353, China.
Microtextured microneedles are tiny needle-like structures with micron-scale microtextures, and the drugs stored in the microtextures can be released after entering the skin to achieve the effect of precise drug delivery. In this study, the skin substitution model of Ogden's hyperelastic model and the microneedle array and microtexture models with different geometrical parameters were selected to simulate and analyse the flow of the microtexture microneedle arrays penetrating the skin by the finite-element method, and the length of the microneedles was determined to be 200 μm, the width 160 μm, and the value of the gaps was determined to be 420 μm. A four-pronged cone was chosen as the shape of microneedles, and a rectangle was chosen as the shape of the drug-carrying microneedle.
View Article and Find Full Text PDFPurpose: This study compares and evaluates the parameters of iridotrabecular contact (ITC) in patients with primary angle closure disease (PACD) with natural lenses and pseudophakia based on anterior segment imaging data from swept-source optical coherence tomography (SS-OCT).
Material And Methods: This retrospective study analyzed data from 92 patients aged 32 to 89 years, and included 56 patients with PACD (43 with natural lenses and 13 with pseudophakia) and 36 in the control group (21 with natural lenses and 15 with pseudophakia). All participants underwent SS-OCT (CASIA2; Tomey Corporation, Japan), which included an assessment of the ITC Index and ITC Area.
Sci Rep
December 2024
Key Laboratory of Special Engineering Equipment Design and Intelligent Driving Technology, Guilin University of Aerospace Technology, Guilin, 541004, China.
This paper purposed to prepare poly (lactic acid)/continuous cotton thread (PLA /CCT) filaments by using prepreg method, and investigated the properties of PLA/CCT filament and their 3D printed composites. Firstly, a prepreg device was home-made to immerse CCT with PLA melts. The effects of the dragging speed and tensioning equipment on the quality of PLA/CCT filament was investigated.
View Article and Find Full Text PDFSci Rep
December 2024
Laboratory of Bioelectric and Bioenergetic Systems, Faculty of Biomedical Engineering, Technion-Israel Institute of Technology, Haifa, Israel.
The standard polygraph, or lie detector, is limited by its reliance on average heart rate, subjective examiner interpretation, and the need for direct subject contact. Remote photoplethysmography (rPPG) offers a promising contactless alternative, by using facial videos to extract heart rate variability (HRV). We introduce "LieRHRV," a remote lie detection algorithm based solely on extracted HRV parameters.
View Article and Find Full Text PDFClin Biomech (Bristol)
December 2024
Masuhara Clinic, 3-4-2, Tenmabashi, Kita-ku, Osaka 530-0042, Japan.
Background: Few studies have assessed vertical ground reaction force, contact time, contact area, and center of pressure during gait in the early phase post-total hip arthroplasty. This study aimed to investigate whether these parameters are more pronounced in participants post-total hip arthroplasty compared to healthy controls.
Methods: We included 22 female participants who underwent total hip arthroplasty (age, 68.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!