Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective(s): To explored the antifertility effectiveness and influence on the endometrium of a micro-copper/low-density polyethylene/methyl vinyl silicone rubber (Cu/LDPE/MVQ) composite in rhesus macaques.
Study Design: Healthy reproductive aged female rhesus macaques underwent abdominal hysterotomy for surgical placement of either the experimental Cu/LDPE/MVQ composite (Cu/LDPE/MVQ, n=5), bare copper wire (Cu, n=5), or hysterotomy only sham-operation group [(SOI, n=4), (SOII, n=6)]. Females in the Cu/LPDE/MVQ, Cu, and SOI groups were housed with fertile males for approximately three menstrual cycles. We assessed pregnancy by hysterectomy. Females in the Cu/LDPE/MVQ, Cu, and SOII groups underwent hysterectomy at about 4 months post-insertion for histologic assessment of morphologic changes of the endometrium, evaluation of materials using scanning electron microscopy (SEM), and evaluation of the inflammatory markers, including substance P receptor (SPR), associated with endometrial bleeding using enzyme linked immunosorbent assay, quantitative RT-PCR, and Western blot analyses.
Results: All of the SOI group females became pregnant (4/4, 100%). In contrast, no pregnancies occurred in either the Cu/LDPE/MVQ (0/5, 0%) or Cu (0/5, 0%) groups. We observed histologic features consistent with chronic endometrial inflammation in all females of the Cu group, but none of the SOII or Cu/LDPE/MVQ animals. Levels of inflammatory markers were significantly increased in the Cu group, compared with SOII or Cu/LDPE/MVQ groups (p<.05). SEM showed evidence of corrosion in the Cu wire not seen in the Cu/LDPE/MVQ group.
Conclusion(s): Cu/LDPE/MVQ material provided a contraceptive effect similar to Cu in macaques, with a lower impact on inflammation and inflammatory markers of the endometrium.
Implications: This study demonstrates the possibility of a Cu/LDPE/MVQ composite as an alternative to conventional copper device materials.