A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Effectiveness and safety of two phototherapy devices for the humanised management of neonatal jaundice]. | LitMetric

Introduction: Neonatal jaundice is common, especially in premature infants. Compliance with treatment protocols and standard serum bilirubin curves forces the clinician to separate the child from the mother after birth for short phototherapy. The objective of this study is to evaluate the effectiveness and safety of two innovative devices for phototherapy including a LED light mesh: one sleeping bag and one blanket compared to conventional hospital or ambulatory phototherapy.

Methods: Two randomised clinical trials were conducted: one with newborns >2,000g at birth in the Neonatal Care Unit and the other with premature infants followed-up in an outpatient clinic (PMC). The gold standard for bilirubin measurement was serum bilirubin, and ambulatory controls were performed with the Bilicheck®. Parents and health personnel completed a questionnaire on comfort and perceptions.

Results: In the study using the bag, a linear regression was performed for the decrease in bilirubin in mg/dL/h, controlling by early jaundice (<36h) and the device type. The results were similar between the 2 devices. For the blanket trial in the PMC, the decrease in bilirubin levels with the new device was significantly greater with no differences in temperatures, duration of phototherapy, re-admission, mortality, or side effects for both trials. Parents and staff satisfaction with the two devices was identical for the 2 trials.

Conclusion: These 2 small studies add a 'grain of sand' to humanisation of newborn care, avoiding the mother-and-child separation for both the intra-hospital high-risk hyperbilirubinaemia, as well as for the lower-risk hyperbilirubinaemia in an outpatient clinic.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.anpedi.2019.02.008DOI Listing

Publication Analysis

Top Keywords

premature infants
8
serum bilirubin
8
[effectiveness safety
4
safety phototherapy
4
phototherapy devices
4
devices humanised
4
humanised management
4
management neonatal
4
neonatal jaundice]
4
jaundice] introduction
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!