Elevation of high-sensitivity cardiac troponin T (hs-cTnT) is associated with an increased risk of cardiovascular disease (CVD). This study determined whether hs-cTnT was detectable with N-terminal pro-b-type natriuretic peptide (NT-proBNP) and related to CV risk factors in a general Japanese population. The Tohoku Medical Megabank Organization pooled individual participant data for a population-based cohort study in the Iwate prefecture ( = 30,193, age = 60.2 ± 11.5 year). Hs-cTnT levels were higher in participants with hypertension, diabetes mellitus than in participants without these conditions (all s < 0.001). Logistic regression analysis demonstrated that NT-proBNP was strongly associated with elevation of hs-cTnT (OR = 3.35, 95% CI = 2.90-3.89,  < 0.001). The receiver operating characteristic curve analysis showed that hs-cTnT was one of useful biomarker for the differentiation of high risk for CVD (the Suita score ≥ 56) from a general population. Logistic regression analysis demonstrated hs-cTnT levels were related to the CVD high risk group (OR = 2.67, 95% CI = 2.28-3.14,  < 0.001). Hs-cTnT levels are associated with elevation of NT-proBNP and high Suita score, which suggests that elevated hs-cTnT is related to subclinical myocardial damage and indicates CV risk.

Download full-text PDF

Source
http://dx.doi.org/10.1080/1354750X.2019.1606278DOI Listing

Publication Analysis

Top Keywords

high-sensitivity cardiac
8
cardiac troponin
8
general japanese
8
japanese population
8
population tohoku
8
tohoku medical
8
medical megabank
8
association high-sensitivity
4
troponin future
4
future cardiovascular
4

Similar Publications

The Fontan operation has become the primary palliative treatment for patients with a functionally univentricular heart. The population of patients with Fontan circulation is constantly growing and aging. As the number of Fontan patients surviving into adulthood increases, there is a clear need for research on how best to follow these patients and manage their complications.

View Article and Find Full Text PDF

Pre-Hospital Point-of-Care Troponin: Is It Possible to Anticipate the Diagnosis? A Preliminary Report.

Diagnostics (Basel)

January 2025

UOC Emergenza Territoriale 118 Area Provinciale Aretina, Azienda USL Toscana Sud-Est, 52100 Arezzo, Italy.

: Thanks to the evolution of laboratory medicine, point-of-care testing (POCT) for troponin levels in the blood (hs-cTn) has been greatly improved in order to quickly diagnose acute myocardial infarction (AMI) with an accuracy similar to standard laboratory tests. The rationale of the HEART POCT study is to propose the application of the 0/1 h European Society of Cardiology (ESC) algorithm in the pre-hospital setting using a POCT device (Atellica VTLi). : This is a prospective study comparing patients who underwent pre-hospital point-of-care troponin testing (Atellica VTLi) with a control group that underwent standard hospital-based troponin testing (Elecsys).

View Article and Find Full Text PDF

Background: Extreme hemodynamic changes, especially intraoperative hypotension (IOH), are common and often prolonged during Liver Transplant (LT) surgery and during initial hours of recovery. Hypotension Prediction Index (HPI) software is one of the tools which can help in proactive hemodynamic management. The accuracy of the advanced hemodynamic parameters such as Cardiac Output (CO) and Systemic Vascular Resistance (SVR) obtained from HPI software and prediction performance of the HPI in LT surgery remains unknown.

View Article and Find Full Text PDF

(1) Background: There are little data about the differences in clinical and echocardiographic characteristics between elderly (aged ≥ 65 years) and younger patients with acute pulmonary embolism (PE). (2) Methods: Consecutive patients diagnosed with PE in a tertiary hospital were identified. Clinical characteristics, biomarkers and transthoracic echocardiography indices including right ventricular free wall longitudinal strain (RV-FWLS) were recorded.

View Article and Find Full Text PDF

The early monitoring of cardiovascular biomarkers is essential for the prevention and management of some cardiovascular diseases. Here, we present a novel, compact, and highly integrated skin electrode as a mechanical-electrochemical dual-model E-skin, designed for the real-time monitoring of heart rate and sweat ion concentration, two critical parameters for assessing cardiovascular health. As a pressure sensor, this E-skin is suitable for accurate heart rate monitoring, as it exhibits high sensitivity (25.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!