New Design Process for Anatomically Enhanced Osteosynthesis Plates.

J Orthop Res

Professor for Innovative Concepts and Technologies in Healthcare, Institute for Medical Technology, Ostbayerische Technische Hochschule (OTH) Amberg-Weiden, Hetzenrichter Weg 15, 92637, Weiden, Germany.

Published: July 2019

This study evaluated the implementation and effectiveness of an iterative process aimed to quantify and enhance the anatomical fit of an osteosynthesis plate design for the fifth metacarpal bone regarding a defined shape-based acceptance criterion (SAC) while complying with basic clinical requirements and engineering limitations. The process was based on employing virtual tools (a database of individual three-dimensional bone models, statistical analysis of the bone geometry, and proprietary software tools) to evaluate conformity between plate designs and bone shape. The conformity was quantified by the mean distance between plate and bone (MBP). The enhancement was completed when the median MBP of the population was below the SAC threshold. This was fulfilled by the third plate design (two enhancement iterations). The intentionally abstract enhancement process may serve as a guideline for development of plate designs for other indications. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 37:1508-1517, 2019.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jor.24299DOI Listing

Publication Analysis

Top Keywords

plate design
8
plate designs
8
plate
5
bone
5
design process
4
process anatomically
4
anatomically enhanced
4
enhanced osteosynthesis
4
osteosynthesis plates
4
plates study
4

Similar Publications

Background: This study was conducted to identify the impacts of the healthy plate model workshop on 4th-graders nutrition knowledge, behaviors, and habits.

Methods: The study was conducted from March to June 2023 in the Uskudar district of Istanbul, involving 102 children (50% girls) with a mean age of 10.2 ± 0.

View Article and Find Full Text PDF

Twin block appliances are commonly used to treat skeletal class II malocclusion. However, many adverse effects, such as lower incisor protrusion and a bulky nature, can be observed. To overcome these effects, a modified twin block was designed, which uses vacuum-formed hard plates (VFPs) instead of acrylic plates.

View Article and Find Full Text PDF

Background: Improvements in cementless total hip arthroplasty have been directed at optimizing osseointegration of the femoral implant to reduce aseptic loosening rates. Stem design plays a critical role in the performance of these implants. Given the increase in new stem designs and the creation of an updated classification system, improved understanding of the outcomes of each stem type is warranted.

View Article and Find Full Text PDF

There are many approaches to the wrist both volar and dorsal, depending on the injury at hand. The design of the volar locking plate has created a rise in distal radius fractures being treated using a volar FCR approach and its modifications. It does, however, have limitations in visualization of the volar ulnar corner of the radius.

View Article and Find Full Text PDF

Background: A large urogenital hiatus in Level III results in a higher risk of developing pelvic organ prolapse after birth and failure after prolapse surgery. Deepening of the pelvic floor and downward rotation of the levator plate have also been linked to prolapse. Currently we lack data that evaluates how these measures relate to one another and to prolapse occurrence and size.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!