Rapid detection techniques and methods of blood coagulation have attracted wide attention in academia and the business community in the presence of the increased demands for rapid assessment (point-of-care testing) of patients from surgery, intensive care unit, and other departments. The differential equation of vibration system composed of elastic support and electromagnetic induction devices was set up using the principle of damping vibration and establishing the dynamics model; meanwhile, the harmonic response analysis and vibration fatigue coupling analysis were carried out, the analysis results were optimized, and the experimental device of the electromagnetic induction testing sensor was established. In addition, the experimental device with blood coagulation reagent was assorted to establish the standard point-of-care testing rapid blood coagulation detection curve, and to compare the testing curve with that of the imported point-of-care testing blood coagulation instrument. The results showed that the first-order natural frequency of the designed sensor was 102.35 Hz, the correlation between the designed sensor and the imported equipment was 0.996, and the testing repeatability of the designed sensor could reach 0.002. Therefore, the designed blood coagulation testing sensor based on electromagnetic induction had the characteristics of favorable elasticity and anti-fatigue, which could meet the accuracy requirements of clinical detection. Taken together, this study could provide the core technology for developing the point-of-care testing instrument for blood coagulation dynamic testing.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0954411919837308DOI Listing

Publication Analysis

Top Keywords

blood coagulation
28
point-of-care testing
16
testing sensor
12
electromagnetic induction
12
designed sensor
12
testing
10
coagulation dynamic
8
dynamic testing
8
sensor based
8
based electromagnetic
8

Similar Publications

Exploring the potential of soapstock over a glycerol in vitamin K2 production by Bacillus subtilis natto: a comparative analysis.

Microb Cell Fact

December 2024

Department of Microbiology, School of Biology, College of Science, University of Tehran, Tehran, 1417864411, Iran.

Background: Vitamin K2 is an essential nutrient for blood coagulation and cardiovascular health and mainly produced by bacteria strain like B. subtilis. researchers have explored producing strain improvement, cultivation mode, environmental optimization, increased secretion, and using cheaper carbon and nitrogen sources in order to increase vitamin K2 productivity.

View Article and Find Full Text PDF

Purpose: Pediatric patients undergoing neurosurgery pose risk of perioperative hemorrhage and clotting dysfunction which is increased in tumors with high vascularity, endothelial exposure, and necrosis. Lesions affecting the ventricular system may arise from several etiologies, including rare tumors. The present study aimed to study the preoperative coagulation and transfusion profile of pediatric patients undergoing neurosurgery for intraventricular lesions.

View Article and Find Full Text PDF

Coronary artery bypass grafting (CABG) with cardiopulmonary bypass (CPB) is associated with the transient activation of a systemic inflammatory response. Fibronectin (FN), an endogenous inflammatory mediator, is a key component of the extracellular matrix. This study aimed to detect changes in cellular and plasma FN levels, as well as its potential fragmentation or FN-fibrin complex formation, in 40 patients undergoing CABG with CPB.

View Article and Find Full Text PDF

Background: Hemophilia B, or Christmas disease, is a hemorrhagic inherited disorder. Previous studies have reported measurement discrepancies in factor VIII activity between clot-based and chromogenic assays in approximately one-third of patients with non-severe hemophilia A. However, similar discrepancies in hemophilia B have been less extensively studied.

View Article and Find Full Text PDF

Until the beginning of the century, bleeding management was similar in elective surgeries or exsanguination scenarios: clotting tests were used to guide blood product orders and, while awaiting these results, an aggressive resuscitation with crystalloids was recommended. The high mortality rate in severe hemorrhages managed with this strategy endorsed the need for a special resuscitation plan. As a result, modifications were recommended to develop a new clinical approach to these patients, called "Damage Control Resuscitation".

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!