Effect of heat-treatment on the pH sensitivity of stainless-steel electrodes as pH sensors.

Heliyon

HORIBA Advanced Techno, Co., Ltd., 2 Miyanohigasi, Kisshoin, Minami-Ku, Kyoto, 601-8551, Japan.

Published: March 2019

Effect of heat-treatment on the pH sensitivity of uncoated stainless-steel electrodes was investigated to comprehend the pH sensitivity of metal-oxide coated stainless-steel electrodes as novel pH sensors. The pH sensitivity of stainless-steel electrodes as-received and heat-treated at 500 °C, 600 °C and 700 °C for 24 h were 91 %, 94 %, 102 % and 91 %, respectively. The pH sensitivity tended to increase with increasing heat-treatment time at a given temperature. Thus, the most suitable heat-treatment condition for the stainless-steel electrodes was 600 °C for 24 h. The austenite phase (fcc) was the main phase on the surface of the heat-treated stainless-steel electrodes. Unexpectedly, the change in the martensite phase (bcc) as the second phase with heat-treatment temperature was similar to the pH sensitivity, with the martensite phase affecting the pH sensitivity. Therefore, it appeared that the pH sensitivity of the metal-oxide coated stainless-steel electrodes was affected by the underlying stainless-steel as well as the outer metal-oxide film coating. A prototype stainless-steel tube electrode was used as a working electrode for demonstrating the depth profiling of pH. The stainless-steel tube electrode showed good performance for measuring pH depth profiles compared to commercially available glass electrodes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6441752PMC
http://dx.doi.org/10.1016/j.heliyon.2019.e01239DOI Listing

Publication Analysis

Top Keywords

stainless-steel electrodes
28
stainless-steel
10
heat-treatment sensitivity
8
sensitivity stainless-steel
8
electrodes
8
sensitivity metal-oxide
8
metal-oxide coated
8
coated stainless-steel
8
600 °c
8
martensite phase
8

Similar Publications

Rapid detection of pork quality has garnered increasing attention due to its status as one of the most widely consumed meats in the world. This study developed an electrochemical impedance combined with sensory evaluation method to achieve real-time imaging and quality assessment of pork. The optimal parameters for pork detection were determined through system performance tests and a Design of Experiment, which included the use of an adjacent excitation pattern, an excitation current of 15 mA at 10 kHz, a detector diameter of 5 cm, and stainless-steel electrodes embedded in the pork.

View Article and Find Full Text PDF

Electrochemical Detection of Hydrogen Peroxide at High Concentrations Using Hastelloy G35 Electrode.

Langmuir

January 2025

State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun, Jilin 130022, P R China.

The detection of hydrogen peroxide (HO) at elevated concentrations while eliminating oxygen interference presents a significant challenge. Nickel-based stainless steel, such as Hastelloy G35, has shown excellent corrosion resistance. However, it has never been used in electroanalysis.

View Article and Find Full Text PDF

A previous companion paper introduced a current pathways model that represents the electrical coupling between the Hall effect thruster (HET) and the ground-based vacuum test facility operational environment. In this work, we operated a 7-kW class HET at 4.5 kW, 15 A and 6 kW, 20 A on krypton to quantify aspects of the current pathways model to characterize the role metal vacuum chambers play in the thruster's discharge circuit as a function of discharge current.

View Article and Find Full Text PDF

Multifunctional ortho-quinones are required for the formation of thiol-catechol-connectivities (TCC) but can be delicate to handle. We present the electrochemical oxidation of the dipeptide DiDOPA, achieving up to 92 % conversion efficiency of the catechols to ortho-quinones. Graphite and stainless steel could be employed as cost-efficient electrodes.

View Article and Find Full Text PDF

Zeolite coatings are studied as molecular sieves for membrane separation, membrane reactors, and chemical sensor applications. They are also studied as anticorrosive films for metals and alloys, antimicrobial and hydrophobic films for heating, ventilation, and air conditioning, and dielectrics for semiconductor applications. Zeolite coatings are synthesized by hydrothermal, ionothermal, and dry-gel conversion approaches, which require high process temperatures and lengthy times (ranging from hours to days).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!