A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Importance of measurement of the diameter of the distal radial artery in a distal radial approach from the anatomical snuffbox before coronary catheterization. | LitMetric

Coronary catheterization by a distal radial approach at the site of the anatomical snuffbox has recently been reported to be both safe and useful. No data are available on the diameter of the distal radial artery (DRA) in Japan, and it is unclear whether the DRA is large enough to withstand the insertion of a conventional sheath by a traditional radial approach. We enrolled 142 patients who underwent coronary catheterization and evaluated the vessel diameter of the DRA using ultrasound. The vessel diameter of the DRA in the anatomical snuffbox (2.6 ± 0.5 mm) was significantly smaller than that of the proximal radial artery (PRA) at the conventional puncture site (3.1 ± 0.4 mm). The difference in vessel diameter between the DRA and PRA was 0.5 ± 0.4 mm, and the DRA/PRA ratio was 0.8 ± 0.1. Although the vessel diameter of the DRA was positively correlated with that of the PRA (r = 0.66, p < 0.0001), in some cases the DRA was extremely small compared to the PRA. When the vessel diameter of the DRA is smaller than the outer diameter of the sheath scheduled for use, we should puncture the PRA at the outset. We could perform coronary catheterization by a distal radial approach without major bleeding or adverse events, and there was no radial artery occlusion at the site of the anatomical snuffbox or the forearm. For coronary catheterization by a distal radial approach, we should evaluate whether there is sufficient vessel diameter using ultrasound before the procedure. In addition, this approach can be an effective option from the viewpoint of radial artery preservation.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00380-019-01404-2DOI Listing

Publication Analysis

Top Keywords

distal radial
16
vessel diameter
16
diameter dra
16
radial artery
12
radial approach
12
anatomical snuffbox
12
coronary catheterization
12
diameter distal
8
radial
6
dra
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!