LED-Cured Reflection Gratings Stored in an Acrylate-Based Photopolymer.

Polymers (Basel)

Departamento de Óptica, Farmacología y Anatomía, Universidad de Alicante, Apartado de correos 99, Alicante E-03080, Spain.

Published: April 2019

The storage of volume holographic reflection gratings in low-toxicity photopolymers represents a challenge at present since they can be used in many important applications such as biosensors and holographic optical elements. In this context, an acrylate-based photopolymer developed in our research group was employed to study the recording of unslanted holographic reflection gratings at high spatial frequencies. The optimal preparation conditions of the photopolymer layers were determinated. The diffraction efficiencies are measured in both recording and curing stage and a comparative study of these values was realized. In addition, a theoretical study using Kogelnik's coupled wave theory was carried out with the aim of understanding the diffraction efficiency behaviour of both processes. In this work, a maximum diffraction efficiency of 14.1% was reached after a curing process in 150 µm layers at a recording wavelength of 488 nm. This value represents a good result compared to that reported in the literature and opens the way to reflection mode holography research using low-toxicity material.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6523380PMC
http://dx.doi.org/10.3390/polym11040632DOI Listing

Publication Analysis

Top Keywords

reflection gratings
12
acrylate-based photopolymer
8
holographic reflection
8
diffraction efficiency
8
led-cured reflection
4
gratings stored
4
stored acrylate-based
4
photopolymer storage
4
storage volume
4
volume holographic
4

Similar Publications

Critical Design and Operating Parameters of Active Waveguide Bragg Gratings for Laser Performance.

Micromachines (Basel)

November 2024

Applied Physics Department, Engineering Research Institute of Aragon (I3A), Faculty of Science, University of Zaragoza, Pedro Cerbuna 12, 50009 Zaragoza, Spain.

Active waveguide Bragg gratings (AWBGs) are promising photonic structures that combine the very efficient reflective properties of a Bragg grating with the power amplification character of rare earths. This combination may lead to a potential monolithic laser under the proper conditions. However, the photonic response of these structures highly depends on the grating design and operating parameters, so modeling its response for their laser performance is a must.

View Article and Find Full Text PDF

In this paper, we demonstrated a novel bidirectional high-speed transmission system integrating a free-space optical (FSO) communication with a 5G wireless link, utilizing a high-power erbium-doped fibre amplifier (EDFA) for enhanced loss compensation. The system supports downlink rates of 1-Gb/s/4.5-GHz and 10-Gb/s at 24-GHz and 39-GHz, and an uplink rate of 10-Gb/s/28-GHz.

View Article and Find Full Text PDF

An objective soft x-ray flat-field spectrograph employing a laminar-type bilayer coated, varied-line-spacing, spherical grating was designed to improve the detection limit and sensitivity of soft x-ray flat-field spectrographs in a region of 250-550 eV. As a design criterion, spectral flux, SF, [Hatano et al., Appl.

View Article and Find Full Text PDF

Under natural conditions, animals repeatedly encounter the same visual scenes, objects or patterns repeatedly. These repetitions constitute statistical regularities, which the brain captures in an internal model through learning. A signature of such learning in primate visual areas V1 and V4 is the gradual strengthening of gamma synchronization.

View Article and Find Full Text PDF

Monitoring of real-time flow and defects in the vacuum-assisted resin infusion (VARI) process can provide important guidelines for full impregnation of dry reinforcement. A weak fiber Bragg grating array was employed to obtain quasi-distributed monitoring results in real-time. Sensitivity testing of different kinds of coated optical fiber sensors (OFs) was carried out first, and the polyacrylate-coated OF showed a greater wavelength-shift response than the polyimide-coated one.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!