Objectives: The aim of this study was to evaluate the middle term cup survival, assess the functional implementation and the radiographic evolution of tantalum acetabular cups implanted on patients with a history of pelvic radiotherapy.

Methods: From 2005 to 2013, we performed 12 THA replacements (4 males 8 females; mean age: 46.6 years (range 25-75)) on irradiated bone with Trabecular metal acetabular cups, 8 primary implants and 4 revision implants. The mean radiation dose delivered was 5500 cGy (range 3000 cGy-13,600 cGy). The mean follow-up was 68 months, ranging from 38 to 136. Postoperative follow-up time was assessed at 1, 3, 6 and 12 months, then annually. Double projection radiographs were requested at each control. Radiographic signs of loosening were investigated by X-rays looking for radiolucent lines. We used the Harris hip score for the clinical and functional evaluation.

Results: To now none of the 12 patients in the series needed any revision surgery for aseptic loosening. In the revision group one patient have been revised for septic loosening, two patients have been treated by conservative procedure for hip dislocation. Post-operative Harris hip score improved from an average of 46 points to 85.3 points. At last follow-up we found only in one case radiographic signs of progressive lucent line, without clinical sign of failure.

Conclusion: In a clinical setting, tantalum cup seems to provide a good stability due to the integration of the trabecular metal to the underline cancellous bone. The reported results, in agreement with literature data, propose the use of tantalum cups in irradiated bone.

Level Of Evidence: Level IV, therapeutic study.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6599415PMC
http://dx.doi.org/10.1016/j.aott.2019.03.007DOI Listing

Publication Analysis

Top Keywords

acetabular cups
12
middle term
8
tantalum acetabular
8
trabecular metal
8
radiographic signs
8
harris hip
8
hip score
8
tantalum
4
term tantalum
4
cups
4

Similar Publications

Background: Different methods can help to optimise sagittal cup orientation in total hip arthroplasty (THA) based on individual spinopelvic characteristics. This study aimed to: (1) assess how often combined sagittal index (CSI) and hip-spine-classification targets were achieved post THA; (2) compare anteversion/inclination between cups in-/outside optimal CSI zone; and (3) determine association with outcome.

Methods: This is a multicentre, prospective, case-cohort study of 435 primary THA for osteoarthritis (53% females; age: 65 ± 12 years; follow-up: 2.

View Article and Find Full Text PDF

Introduction: The RM Pressfit vitamys is an uncemented, titanium particle-coated, isoelastic monoblock cup made of vitamin E blended highly cross-linked polyethylene. We addressed the following questions: (1) What are the clinical and (2) radiographic outcomes 10 years after implantation? (3) What is the revision rate?

Methods: In this prospective observational study in a tertiary care centre we investigated all consecutive cases of total hip replacement with the RM Pressfit vitamys cup between September 2009 and November 2011. It was implanted in 162 hips, 49.

View Article and Find Full Text PDF

Objective: The primary research aim was to determine if the use of traditional or 3D printed prosthesis resulted in better functional outcome scores in hip arthroplasty.

Methods: A systematic review and meta-analysis was conducted utilizing the PRISMA 2020 guidelines. Six databases (PubMed, Embase, Scopus, WebOfScience, and Cochrane Library, Google Scholar) were searched yielding 1117 article titles and abstracts.

View Article and Find Full Text PDF

Introduction: Robot-assisted instrumentation during total hip arthroplasty (THA) has the potential to improve acetabular cup positioning. This study aimed to evaluate the precision of robotic-arm-assisted THA (rTHA) and assess whether the system can provide accurate cup positioning comparable to conventional THA (cTHA).

Methods: A single-center prospective cohort study consisting of 151 patients who underwent THA (108 rTHA and 43 cTHA).

View Article and Find Full Text PDF

The influence of PEEK acetabular shell on the mechanical stability of total hip replacements under gait loading and motion.

Med Biol Eng Comput

December 2024

Sch Mech Engn, Southwest Jiaotong Univ, Chengdu, 610031, People's Republic of China.

The demand for total hip replacement surgery is increasing year by year. However, the issue of hip prosthesis failure, particularly the modular acetabular cup, still exists. The performance and functional requirements of modular acetabular cups have not yet met clinical expectations.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!