https://eutils.ncbi.nlm.nih.gov/entrez/eutils/efetch.fcgi?db=pubmed&id=30953918&retmode=xml&tool=pubfacts&email=info@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908https://eutils.ncbi.nlm.nih.gov/entrez/eutils/esearch.fcgi?db=pubmed&term=aebsf-related+impurities&datetype=edat&usehistory=y&retmax=5&tool=pubfacts&email=info@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908 Quantification of residual AEBSF-related impurities by reversed-phase liquid chromatography. | LitMetric

Quantification of residual AEBSF-related impurities by reversed-phase liquid chromatography.

J Chromatogr B Analyt Technol Biomed Life Sci

Vaccine Production Program, Vaccine Research Center, National Institute of Allergy and Infectious Diseases, National Institutes of Health, Gaithersburg, MD, USA. Electronic address:

Published: May 2019

During research of a broadly neutralizing antibody (bNAb) for HIV-1 infection, site-specific clipping was observed during cell culture incubation. Protease inhibitor, 4-(2-aminoethyl) benzenesulfonyl fluoride (AEBSF), was supplemented to the cell culture feeding to mitigate clipping as one of the control strategies. It led to the need and development of a new assay to monitor the free AEBSF-related impurities during the purification process. In this work, a reversed-phase liquid chromatography (RPLC-UV) method was developed to measure the total concentration of AEBSF and its major degradant product, 4-(aminoethyl) benzenesulfonic acid (AEBS-OH). This quantitative approach involved hydrolysis pre-treatment to drive all AEBSF to AEBS-OH, a filtration step to remove large molecules, followed by RPLC-UV analysis. The method was qualified and shown to be capable of measuring AEBS-OH down to 0.5 μM with good accuracy and precision, which was then applied for process clearance studies. The results demonstrated that a Protein A purification step in conjunction with a mock ultrafiltration/diafiltration (UF/DF) step could remove AEBSF-related impurities below the detection level. Overall, this study is the first to provide a unique approach for monitoring the clearance of free AEBSF and its related degradant, AEBS-OH, in support of the bNAb research.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7439605PMC
http://dx.doi.org/10.1016/j.jchromb.2019.03.022DOI Listing

Publication Analysis

Top Keywords

aebsf-related impurities
12
reversed-phase liquid
8
liquid chromatography
8
cell culture
8
step remove
8
quantification residual
4
residual aebsf-related
4
impurities reversed-phase
4
chromatography broadly
4
broadly neutralizing
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!