A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Deformation and retentive force following in vitro cyclic fatigue of cobalt-chrome and aryl ketone polymer (AKP) clasps. | LitMetric

Objective: To compare the retention force of individual clasps made from cobalt chromium (CoCr) or new aryl ketone polymer (AKP) material, Ultaire™ AKP, following prolonged fatigue testing along ideal and non-ideal paths of removal and to assess 3D deformation of the active and passive clasp tips.

Methods: CoCr and AKP clasps were manufactured in their standard, respective processes, digitally scanned prior to testing, then cycled 15,000 times over an e.max analogue crown in artificial saliva. Retentive load was measured in situ, as a function of cycles. Clasps were rescanned to assess deformation and along with their antagonists subjected to SEM to assess localised wear.

Results: Distortion of the CoCr clasps was consistently larger than Ultaire™ AKP clasps, irrespective of removal path. CoCr clasps had significantly higher retentive forces than AKP clasps, for both removal paths. Ultaire™ AKP clasps showed a lower but relatively constant retentive force. The non-ideal path of removal affected retentive forces for both clasp materials. SEM showed localised removal of glaze for e.max crowns used with CoCr clasps.

Significance: Ultaire™ AKP clasps showed significantly less permanent deformation and lower retentive force than CoCr clasps. Unlike CoCr, the Ultaire™ AKP clasps did not work harden, nor had as large a reduction in retentive force and accompanying permanent deformation; the retentive force for the Ultaire™ AKP clasps was consistent over 15,000 cycles of fatigue mimicking prolonged clinical use. The AKP material was more robust; showing minimal deformation even in non-ideal paths of removal, as many patients would routinely use.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.dental.2019.02.028DOI Listing

Publication Analysis

Top Keywords

akp clasps
32
ultaire™ akp
24
retentive force
20
clasps
13
cocr clasps
12
akp
11
deformation retentive
8
aryl ketone
8
ketone polymer
8
polymer akp
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!