Therapeutic contact lenses were developed from bacterial cellulose (BC) by the Institute of Chemistry at Brazil's São Paulo State University (UNESP). In a previous study, cyclodextrins (CD) and medications such as ciprofloxacin (CP) and diclofenac sodium (DS) were incorporated into the lenses to provide therapeutic properties and control drug release. However, significant opacity was seen in the material inherent to cellulose. In order to achieve full material transparency, the lenses were coated with an organic-inorganic hybrid compound containing aluminum alkoxide and glycidoxypropyltrimethoxysilane (GPTS)(H), or chitosan (Q) nanoparticles. This study evaluated the toxicity of these contact lenses to ensure the safety of these materials for future availability to the medical device industry. Lenses composed of BC and coated with either GPTS (H) or chitosan (Q), incorporating ciclodextrin (CD) to release diclofenac sodium (DS) or ciprofloxacin (CP), were submitted to cytotoxicity assays (XTT and Clonogenic Survival), genotoxicity (Comet Assay) and mutagenicity (Cytokinesis-blocked micronucleus assay) directly in cell culture. Statistical analyses were performed using the Tukey and Dunnett or Kruskal-Wallis and Dunn tests. All of the nanoparticles used in the lense coatings did not show cytotoxic effects by the XTT test (p > 0.05; Dunnett). Only materials associated with diclofenac sodium (BC-H-CD-DS and BC-Q-CD-DS) presented significantly different survival fractions compared to negative control (p < 0.001; Dunnett). Genotoxicity evaluation revealed a genotoxic effect in BC-H-CD-DS (p < 0.05; Dunn). All tested lenses did not present any mutagenic effect. These results indicate that improvements in DS incorporation are needed to eliminate toxicity. We demonstrated promising results in the safety of employing BC lenses functionalized with a drug delivery system permitting the bioavailability of ophthalmic drugs. Further studies utilizing other specific tests, such as corneal lineage are required before safe and efficient ophthalmologic use.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.clae.2019.03.006 | DOI Listing |
Ophthalmic Physiol Opt
January 2025
School of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia.
Purpose: To assess the repeatability of lipid layer thickness (LLT) measurement using the LipiView® interferometer after daily disposable contact lens (CL) wear and correlation with ocular comfort in soft contact lens wearers.
Methods: A prospective study was conducted over two consecutive months, wherein CL wearers (n = 20) wore either Somofilcon A or Verofilcon A daily disposable CLs in a crossover design, switching lenses after 1 month. The pre-corneal tear film LLT was measured at the end of each month after CLs had been worn for at least 6 h.
Ophthalmic Physiol Opt
January 2025
Contact Lens and Visual Optics Laboratory, Optometry and Vision Science, Centre for Vision and Eye Research, Queensland University of Technology, Brisbane, Queensland, Australia.
Introduction: Tear exchange during contact lens wear is essential for ocular surface integrity, facilitating debris removal, and maintaining corneal metabolism. Fluorophotometry and fluorogram methods are typically used to measure tear exchange, which require hardware modifications to a slit lamp biomicroscope. This manuscript introduces an alternative method using a corneoscleral profilometer, the Eye Surface Profiler (ESP), to quantify tear exchange during corneal and scleral rigid lens wear by assessing fluorescence intensity changes over time.
View Article and Find Full Text PDFAdv Mater
January 2025
Key Laboratory of Green Printing, CAS Research/Education Center for Excellence in Molecular Sciences, Institute of Chemistry, Chinese Academy of Sciences (ICCAS), Beijing Engineering Research Center of Nanomaterials for Green Printing Technology, Beijing National Laboratory for Molecular Sciences (BNLMS), Beijing, 100080, P. R. China.
More than 70% of human information comes from vision. The eye is one of the most attractive sensing sites to collect biological parameters. However, it is urgent to develop a cost-effective and easy-to-use approach to monitor eyeball information in a minimally invasive way instead of current smart contact lenses or camera-based eyeglasses.
View Article and Find Full Text PDFImportance: For myopia control to be beneficial, it would be important that the benefit of treatment (slowed eye growth) is not lost because of faster than normal growth (rebound) after discontinuing treatment.
Objective: To determine whether there is a loss of treatment effect (rebound) after discontinuing soft multifocal contact lenses in children with myopia.
Design, Setting, And Participants: The Bifocal Lenses in Nearsighted Kids 2 (BLINK2) cohort study involved children with myopia (aged 11-17 years at BLINK2 baseline) who completed the BLINK Study randomized clinical trial.
Tunis Med
January 2025
Department of Ophtalmology, Habib Bourguiba University Hospital, University of Sfax, Sfax, Tunisia.
Aim: To report the clinical and therapeutic particularities of pediatric keratoconus (KC).
Methods: Retrospective study focusing on patients aged less than 18 years, presenting with KC and followed in a tertiary reference center in Sfax, Tunisia.
Results: Our study involved 38 eyes of 20 children.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!