Towards compliant small-diameter vascular grafts: Predictive analytical model and experiments.

Mater Sci Eng C Mater Biol Appl

Department of Mechanical Engineering, École de Technologie Supérieure (ÉTS), Montreal, QC H3C 1K3, Canada; Laboratory of Endovascular Biomaterials (LBeV), Research Centre, Centre Hospitalier de l'Université de Montréal (CRCHUM), Montreal, QC H2X 0A9, Canada. Electronic address:

Published: July 2019

The search for novel, more compliant vascular grafts for the replacement of blood vessels is ongoing, and predictive tools are needed to identify the most promising biomaterials. A simple analytical model was designed that enables the calculation of the ratio between the ultimate stress (σ) and the elastic modulus (E). To reach both the compliance of small-diameter coronary arteries (0.0725%/mmHg) and a burst pressure of 2031 mmHg, a material with a minimum σ/E ratio of 1.78 is required. Based on this result and on data from the literature, random electrospun Polyurethane/Polycaprolactone (PU/PCL) tubular scaffolds were fabricated and compared to commercial ePTFE prostheses. PU/PCL grafts showed mechanical properties close to those of native arteries, with a circumferential elastic modulus of 4.8 MPa and a compliance of 0.036%/mmHg at physiological pressure range (80-120 mmHg) for a 145 μm-thick prosthesis. In contrast, commercial expanded polytetrafluoroethylene (ePTFE) grafts presented a high Young's modulus (17.4 MPa) and poor compliance of 0.0034%/mmHg. The electrospun PU/PCL did not however reach the target values as its σ/E ratio was lower than expected, at 1.54, well below the calculated threshold (1.78). The model tended to overestimate both the compliance and burst pressure, with the differences between the analytical and experimental results ranging between 13 and 34%, depending on the pressure range tested. This can be explained by the anisotropy of random electrospun PU/PCL and its slightly non-linear elastic behavior, in contrast to the hypotheses of our model. Impermeability tests showed that the electrospun scaffolds were impermeable to blood for all thicknesses above 50 μm. In conclusion, this analytical model allows to select materials with suitable mechanical properties for the design of small-diameter vascular grafts. The novel electrospun PU/PCL tubular scaffolds showed strongly improved compliance as compared to commercial ePTFE prostheses.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.msec.2019.03.023DOI Listing

Publication Analysis

Top Keywords

vascular grafts
12
analytical model
12
electrospun pu/pcl
12
small-diameter vascular
8
elastic modulus
8
burst pressure
8
σ/e ratio
8
random electrospun
8
pu/pcl tubular
8
tubular scaffolds
8

Similar Publications

Introduction: Since the mid-1900s, techniques in the repair of aortic arch and thoracoabdominal aortic pathologies have drastically evolved. Open aortic surgical repair was once the sole option for both simple and complex aneurysmal degeneration. Today, a number of minimally invasive and hybrid approaches are now available to assist both the surgeon and patient in tackling this challenging problem.

View Article and Find Full Text PDF

Objectives: We aim to evaluate the safety and effectiveness of the Zenith Dissection Endovascular System (ZDES; Zenith TX2 Dissection Endovascular Graft with Pro-Form and Zenith Dissection Endovascular Stent), which uses a proximal stent graft along with a distal bare metal stent compared to traditional stent grafts in the repair of acute, complicated Type B Aortic Dissection (AcTBAD).

Methods: This retrospective study reviews the medical charts of 32 patients with AcTBAD repaired at a single urban academic medical center. 16 of these AcTBAD cases were repaired with the ZDES (87.

View Article and Find Full Text PDF

Liver organoids have been increasingly adopted as a critical in vitro model to study liver development and diseases. However, the pre-vascularization of liver organoids without affecting liver parenchymal specification remains a long-lasting challenge, which is essential for their application in regenerative medicine. Here, the large-scale formation of pre-vascularized human hepatobiliary organoids (vhHBOs) is presented without affecting liver epithelial specification via a novel strategy, namely nonparenchymal cell grafting (NCG).

View Article and Find Full Text PDF

Graft Intolerance Syndrome Complicates Retransplantation.

Transplant Proc

January 2025

Doctor Peset University Hospital, Valencia, Spain; The Foundation for the Promotion of Health and Biomedical Research of the Valencian Community (Fisabio), Valencia, Spain; University of Valencia, Valencia, Spain.

Background: Patients with non-functioning renal grafts constitute approximately 4% of patients with incident dialysis. Complete withdrawal of immunosuppression has been associated with a higher risk of HLA sensitization and renal graft intolerance syndrome (GIS).

Methods: We conducted a retrospective observational study of 63 patients with renal graft failure (from January 2012 to December 2022).

View Article and Find Full Text PDF

Open abdomen treatment (OAT) is associated with significant morbidity and mortality. In cases where primary or delayed fascial closure cannot be achieved, vacuum-assisted wound closure and mesh-mediated fascial traction are indicated, which often result in a planned ventral hernia. If secondary skin closure is not feasible, common treatment of granulated abdominal defects involves split-thickness skin-grafting or healing by secondary intention leading to significant scarring and sometimes mutilating defects.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!