Occlusal support may influence muscular function during complex motor tasks. This study evaluated the duration and sequence of muscular activation of masticatory (temporal, masseter), postural head/neck (sternocleidomastoid, trapezius), postural trunk (rectus abdominis, paravertebrals), and low extremity strength (rectus femoris, gastrocnemius) muscles during simulation of activities of daily living (ADL) in edentulous women wearing complete dentures (n = 10) and in dentate women (n = 10). Electromyographic activity was recorded during tests of stand-up/sit down in the Chair, sit up/lie down in the Bed and lift/lower Bags. Occlusal support (dentures) had a significant effect on duration of muscular activation in the Chair Test: the masseter muscle activated longer with dentures during the standing movement. The masseter and sternocleidomastoid muscles showed significant alteration in their order of activation in non-denture-wearing women. For the Bed Test, dentures had significant effect for the gastrocnemius during the sitting-up phase and for the rectus abdominis during the lying-down movement. For the Bag Test, head/neck muscles were activated in a different order as a function of occlusal support. Anticipation of activation of the paravertebral muscles, rectus abdominis, and gastrocnemius was observed in dentate women compared with denture wearers. These findings suggest that occlusal support influences electromyographic activity of some muscles during simulation of ADL.

Download full-text PDF

Source
http://dx.doi.org/10.1111/eos.12614DOI Listing

Publication Analysis

Top Keywords

occlusal support
16
muscular activation
12
rectus abdominis
12
duration sequence
8
sequence muscular
8
denture wearers
8
simulation activities
8
activities daily
8
daily living
8
muscles simulation
8

Similar Publications

Background Previous studies have suggested that providing dietary guidance along with denture treatment may improve dietary diversity in edentulous patients; however, none have examined the effects on nutritional blood biomarkers. This study investigated the effects of individualized dietary guidance combined with complete denture treatment on nutritional blood biomarker levels, dietary intake, and masticatory function. Materials and methods This was a prospective, randomized, open-label, controlled trial.

View Article and Find Full Text PDF

Introduction: The cant of the occlusal plane in the frontal plane reflects facial asymmetry. Its treatment requires close collaboration between the orthodontist and the maxillofacial surgeon. In case of mild cant, treatment consists in coordination of dental arches followed by mandibular osteotomy.

View Article and Find Full Text PDF

Objectives: To assess the effect of occlusion and implant number/position on stress distribution in Kennedy Class II implant-assisted removable partial denture (IARPD).

Materials And Methods: IARPDs were designed in six models: with one implant (bone level with a platform of 4 mm and length of 10 mm) at the site of (I) canine, (II) between first and second premolars, (III) first molar, (IV) second molar, or two implants at the sites of (V) canine-first molar, and (VI) canine-second molar. A conventional RPD served as control.

View Article and Find Full Text PDF

Mechanical behavior of external root resorption cavities restored with different materials: a 3D-FEA study.

BMC Oral Health

January 2025

Faculty of Dentistry, Department of Endodontics, Ondokuz Mayis University, Samsun, Kurupelit, 55139, Turkey.

Background: The aim was to evaluate the stresses in teeth, with external root resorption (ERR) restored with different materials using finite element analysis (FEA).

Methods: In this study, a Micro-CT scan was conducted on a prepared maxillary central tooth. DICOM-compatible images obtained from the sections were converted into stereolithography format using Ctan software.

View Article and Find Full Text PDF

Background: Anatomically formed healing abutments were suggested in literature to address many of the issues associated with immediate posterior implant insertion such as large extraction sockets that are extremely hard to seal without reflecting the mucoperiosteal flap, extraction sockets anatomy that are not suitable for regular healing abutment placement, and potentially high occlusal stresses when planning a temporary implant supported prothesis to improve the conditioning of supra implant tissue architecture and the emergence profile of the implant supported restorations.

Purpose: To clinically evaluate the peri-implant soft tissue profile of single posterior implant retained restorations and to assess patient related outcomes of the implant restorations that were conditioned immediately by CAD-CAM socket sealing abutments (SSA) versus those conditioned by Titanium (Ti) standard healing abutments (SHA).

Methods: Twenty participants received twenty-two single maxillary immediate implants after flapless minimally invasive tooth extraction and 3D guided implant placement in the posterior area (premolar and molar) and allocated randomly into two groups (n = 11), the intervention group: patients received PEEK SSA and the control group: the patients received Ti SHA.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!