To estimate the neural generators of magnetoencephalographic (MEG) signals, MEG data have to be co-registered with an anatomical image, typically an MR image. Optically-pumped magnetometers (OPMs) enable the construction of on-scalp MEG systems providing higher sensitivity and spatial resolution than conventional SQUID-based MEG systems. We present a co-registration method that can be applied to on-scalp MEG systems, regardless of the number of sensors. We apply a structured-light scanner to create a surface mesh of the subject's head and the sensor array, which we fit to the MR image. We quantified the reproducibility of the mesh and localised current dipoles with a phantom. Additionally, we measured somatosensory evoked fields (SEFs) to median nerve stimulation and compared the dipole positions between on-scalp and SQUID-based systems. The scanner reproduced the head surface with <1 mm error. Phantom dipoles were localised with 2.1 mm mean error. SEF dipoles corresponding to the P35m response for OPMs were well localised to the somatosensory cortex, while SQUID dipoles for two subjects were erroneously localised to the motor cortex. The developed co-registration method is inexpensive, fast and can easily be applied to on-scalp MEG. It is more convenient than traditional co-registration methods while also being more accurate.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6445124 | PMC |
http://dx.doi.org/10.1038/s41598-019-41763-4 | DOI Listing |
Front Neurosci
November 2023
Laboratoire de Neuroimagerie et Neuroanatomie Translationnelles (LN2T), ULB Neuroscience Institute (UNI), Université libre de Bruxelles, Brussels, Belgium.
Cryogenic magnetoencephalography (MEG) enhances the presurgical assessment of refractory focal epilepsy (RFE). Optically pumped magnetometers (OPMs) are cryogen-free sensors that enable on-scalp MEG recordings. Here, we investigate the application of tri-axial OPMs [Rb (Rb-OPM) and He gas (He-OPM)] for the detection of interictal epileptiform discharges (IEDs).
View Article and Find Full Text PDFClin Neurophysiol
December 2023
Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden.
Objective: Epilepsy surgery requires localization of the seizure onset zone (SOZ). Today this can only be achieved by intracranial electroencephalography (iEEG). The iEEG electrode placement is guided by findings from non-invasive modalities that cannot themselves detect SOZ-generated initial seizure activity.
View Article and Find Full Text PDFDev Med Child Neurol
March 2024
Laboratoire de Neuroanatomie et Neuroimagerie Translationnelles, Université libre de Bruxelles, ULB Neuroscience Institute, Bruxelles, Belgium.
Magnetoencephalography (MEG) is a neurophysiological technique based on the detection of brain magnetic fields. Whole-head MEG systems typically house a few hundred sensors requiring cryogenic cooling in a rigid one-size-fits-all (commonly adult-sized) helmet to keep a thermal insulation space. This leads to an increased brain-to-sensor distance in children, because of their smaller head circumference, and decreased signal-to-noise ratio.
View Article and Find Full Text PDFSensors (Basel)
June 2023
Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, UK.
The evolution of human cognitive function is reliant on complex social interactions which form the behavioural foundation of who we are. These social capacities are subject to dramatic change in disease and injury; yet their supporting neural substrates remain poorly understood. Hyperscanning employs functional neuroimaging to simultaneously assess brain activity in two individuals and offers the best means to understand the neural basis of social interaction.
View Article and Find Full Text PDFSensors (Basel)
April 2023
CNBR, Skolkovo Institute of Science and Technology, 121205 Moscow, Russia.
Recently, a new kind of sensor applicable in magnetoencephalography (MEG) has been presented: a solid-state yttrium-iron garnet magnetometer (YIGM). The feasibility of yttrium-iron garnet magnetometers (YIGMs) was demonstrated in an alpha-rhythm registration experiment. In this paper, we propose the analysis of lead-field matrices for different possible multi-channel on-scalp sensor layouts using YIGMs with respect to information theory.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!