A new concept of a dual-chamber serial-parallel piezoelectric pump with an integrated sensor (DSPPIS) is presented in this paper. By means of dividing a piezoelectric bimorph into an actuator and a sensor, sensing function is integrated onto the DSPPIS for flow rate measurement. A prototype of the DSPPIS was manufactured and assembled from a finished piezoelectric bimorph. Then, frequency and voltage characteristics were tested to evaluate the performance of the DSPPIS with serial and parallel connection. Experimental results show that the optimal frequency range of DSPPIS can be achieved and determined by itself through monitoring the sensing voltage when driven by a fixed voltage of 150 Vpp and a frequency range of 40⁻400 Hz. For a fixed frequency of 100 Hz and a voltage range of 50⁻250 Vpp, both the sensing voltage and output flow rate increase with the increase of driving voltage. It is observed that there is a positive correlation between sensing voltage and output flow rate, which was further fitted by using linear function. The correlation coefficients for the DSPPIS with serial and parallel connection are calculated as 0.9716 and 0.9054, respectively. As a result, the DSPPIS demonstrated in this paper has realized the measurement of flow rate without the additional flow-sensing equipment both in serial and parallel connection.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6472054PMC
http://dx.doi.org/10.3390/s19061447DOI Listing

Publication Analysis

Top Keywords

flow rate
20
serial parallel
12
parallel connection
12
sensing voltage
12
piezoelectric pump
8
pump integrated
8
integrated sensor
8
rate measurement
8
piezoelectric bimorph
8
dsppis serial
8

Similar Publications

The shape characteristics of flow hydrographs hold essential information for understanding, monitoring and assessing changes in flow and flood hydrology at reach and catchment scales. However, the analysis of individual hydrographs is time consuming, making the analysis of hundreds or thousands of them unachievable. A method or protocol is needed to ensure that the datasets being generated, and the metrics produced, have been consistently derived and validated.

View Article and Find Full Text PDF

To validate Palestine's previously derived emergency department quality standards (EDQS) using an e-Delphi survey. A two-round e-Delphi survey validated the EDQS, developed in an earlier study through a literature review and consensus-building among Palestinian emergency medicine and healthcare quality experts. The study purposively sampled 53 emergency department and healthcare quality experts with over 5 years of experience.

View Article and Find Full Text PDF

Purpose: This systematic review aimed to assess the updated literature for the prevention of salivary gland hypofunction and xerostomia induced by non-surgical cancer therapies.

Methods: Electronic databases of MEDLINE/PubMed, EMBASE, and Cochrane Library were searched for randomized controlled trials (RCT) that investigated interventions to prevent salivary gland hypofunction and/or xerostomia. Literature search began from the 2010 systematic review publications from the Multinational Association of Supportive Care in Cancer/International Society of Oral Oncology (MASCC/ISOO) up to February 2024.

View Article and Find Full Text PDF

To evaluate the safety and efficacy of staged coiling followed by flow diverter (FD) in the treatment of ruptured intracranial aneurysms(RIAs). A retrospective analysis was conducted on 20 patients with RIAs treated with staged coiling followed by FD at a single center, between April 2015 and September 2024. Patient demographics, aneurysm characteristics, clinical and imaging outcomes were reviewed.

View Article and Find Full Text PDF

A novel employment of single particle-inductively coupled plasma-mass spectrometry (SP-ICP-MS) was developed, where a microextraction (ME) probe is used to sample nanoparticles from a surface and analyze them in a single analytical step. The effects of several parameters on the performance of ME-SP-ICP-MS were investigated, including the flow rate, choice of carrier solution, particle size, and the design of the microextraction probe head itself. The optimized ME-SP-ICP-MS technique was used to compare the extraction efficiency (EE, defined as the ratio of particles measured to particles deposited on the surface) of the commercial probe head to a newly designed SP polyether ether ketone (PEEK) probe head.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!