Purpose: Proton CT (pCT) has the ability to reduce inherent uncertainties in proton treatment by directly measuring the relative proton stopping power with respect to water, thereby avoiding the uncertain conversion of X-ray CT Hounsfield unit to relative stopping power and the deleterious effect of X- ray CT artifacts. The purpose of this work was to further evaluate the potential of pCT for pretreatment positioning using experimental pCT data of a head phantom.

Methods: The performance of a 3D image registration algorithm was tested with pCT reconstructions of a pediatric head phantom. A planning pCT simulation scan of the phantom was obtained with 200 MeV protons and reconstructed with a 3D filtered back projection (FBP) algorithm followed by iterative reconstruction and a representative pretreatment pCT scan was reconstructed with FBP only to save reconstruction time. The pretreatment pCT scan was rigidly transformed by prescribing random errors with six degrees of freedom or deformed by the deformation field derived from a head and neck cancer patient to the pretreatment pCT reconstruction, respectively. After applying the rigid or deformable image registration algorithm to retrieve the original pCT image before transformation, the accuracy of the registration was assessed. To simulate very low-dose imaging for patient setup, the proton CT images were reconstructed with 100%, 50%, 25%, and 12.5% of the total number of histories of the original planning pCT simulation scan, respectively.

Results: The residual errors in image registration were lower than 1 mm and 1° of magnitude regardless of the anatomic directions and imaging dose. The mean residual errors ranges found for rigid image registration were from -0.29 ± 0.09 to 0.51 ± 0.50 mm for translations and from -0.05 ± 0.13 to 0.08 ± 0.08 degrees for rotations. The percentages of sub-millimetric errors found, for deformable image registration, were between 63.5% and 100%.

Conclusion: This experimental head phantom study demonstrated the potential of low-dose pCT imaging for 3D image registration. Further work is needed to confirm the value pCT for pretreatment image-guided proton therapy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6448157PMC
http://dx.doi.org/10.1002/acm2.12565DOI Listing

Publication Analysis

Top Keywords

image registration
28
pct
12
pretreatment pct
12
image
8
registration
8
stopping power
8
pct pretreatment
8
registration algorithm
8
head phantom
8
planning pct
8

Similar Publications

Partial cystectomy as a surgical option for colorectal cancer patients with pathological bladder invasion: an original retrospective study.

Therap Adv Gastroenterol

January 2025

Department of General Surgery (Colorectal Surgery), The Sixth Affiliated Hospital, Sun Yat-sen University, 510655, Guangzhou, Guangdong, China.

Background: Limited research exists on colorectal cancer (CRC) patients with bladder invasion, with survival outcomes post-cystectomy underexplored and a debate between partial and total cystectomy ongoing.

Objective: The study aimed to evaluate the effect of pathological bladder invasion on the long-term tumour prognosis of patients with clinically diagnosed bladder invasion in CRC after cystectomy.

Design: Retrospective, cohort study.

View Article and Find Full Text PDF

Background: Current outcomes from catheter ablation for scar-dependent ventricular tachycardia (VT) are limited by high recurrence rates and long procedure durations. Personalized heart digital twin technology presents a noninvasive method of predicting critical substrate in VT, and its integration into clinical VT ablation offers a promising solution. The accuracy of the predictions of digital twins to detect invasive substrate abnormalities is unknown.

View Article and Find Full Text PDF

Real-world evidence of ocrelizumab in Chilean patients with multiple sclerosis.

Mult Scler

January 2025

Departamento de Neurología, Pontificia Universidad Católica de Chile, Santiago, Chile.

Background: Real-world studies are needed to expand our knowledge concerning populations underrepresented in clinical trials.

Objective: This study aimed to evaluate the safety and effectiveness of ocrelizumab in Hispanic/Latino people with multiple sclerosis (pwMS).

Methods: Prospective longitudinal observational study including pwMS who received at least one dose of ocrelizumab between June 2018 and October 2023.

View Article and Find Full Text PDF

Neutralizing antibody test supports booster strategy for young individuals after SARS-CoV-2 Omicron breakthrough.

Eur J Med Res

January 2025

Department of Ophthalmology, The First Affiliated Hospital of USTC, School of Life Sciences, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, 230026, China.

Background: The SARS-CoV-2 Omicron variant, since its initial detection, has rapidly spread across the globe, becoming the dominant strain. It is important to study the immune response of SARS-CoV-2 Omicron variant due to its remarkable ability to escape the majority of existing SARS-CoV-2 neutralizing antibodies. The surge in SARS-CoV-2 Omicron infections among most Chinese residents by the end of 2022 provides a unique opportunity to understand immune system's response to Omicron in populations with limited exposure to prior SARS-CoV-2 variants.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!