In implantology, when financial or biological feasibility limitations appear, it is necessary to use prostheses with geometries that deviate from the conventional, with a pontic in the absence of an intermediate implant. The aim of this study was analyze and understand the general differences in the stresses generated in implants, components and infrastructures according to the configuration of the prosthesis over three or two implants. Thus, this paper analyzes the von Mises equivalent stresses (VMES) of ductile materials on their external surfaces. The experimental groups: Regular Splinted Conventional Group (RCG), which had conventional infrastructures on 3 regular-length Morse taper implants (4x11 mm); Regular Splinted Pontic Group (RPG), which had infrastructures with intermediate pontics on 2 regular-length Morse taper implants (4x11 mm). The simulations of the groups were created with Ansys Workbench 10.0 software. The results revealed that the RPG presented greater areas of possible fragility due to higher stress concentrations, for example, in the cervical area of the union between the implant and component the top platform of the abutment, as well as greater coverage of the stress by the cervical implant threads. The RPG infrastructure was also more affected by stresses in the connection areas between the prostheses and on the occlusal surface. There is an advantage to using prostheses supported by a greater number of implants (RCG) because this decreases the stress in the analyzed structures and consequently improves stress dissipation to the supporting bone, which would preserve the system.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/10255842.2019.1588254 | DOI Listing |
Med Sci Monit
January 2025
Department of Prosthetic Dental Sciences, College of Dentistry, Jazan University, Jazan, Saudi Arabia.
BACKGROUND A tooth preparation's clinical requirements and geometric configurations should take precedence over material characteristics when advocating for putty reline impression techniques for permanent restorations, since they require a technically sensitive spacer for light body elastomer. We evaluated the linear dimensional accuracy of vinyl polysiloxane-based putty reline impressions with different spacer acquisition techniques in short-span and long-span fixed partial dentures (FPD). MATERIAL AND METHODS A typodont tooth set simulated a 3-unit (short-span) and a 5-unit (long-span) FPD.
View Article and Find Full Text PDFOn the basis of a case, this study considers which prosthetic device is suitable as a replacement for a first molar. At the request of the patient, the least invasive option was sought. The outcome in this case was that the adhesive bridge with abutment teeth with class-2 restorations might be suitable.
View Article and Find Full Text PDFMedicina (Kaunas)
November 2024
Faculty of Medicine and Health Sciences, Department of Prosthodontics, School of Dentistry, University of Barcelona, 08907 Barcelona, Spain.
: Oral rehabilitation seeks to enhance mastication, a vital component of oral function that is compromised by tooth loss. This study aimed to assess the degree of improvement of masticatory performance in partially edentulous patients rehabilitated with removable partial dentures (RPD) or fixed partial dental prosthesis (FPDP). Changes in the occlusal contact area (OCA) and satisfaction with their chewing ability during the adaptation period were also evaluated.
View Article and Find Full Text PDFCureus
October 2024
Prosthodontics, Faculty of Dental Medicine, Mohammed V University, Rabat, MAR.
The management of distal extension edentulism by removable partial denture (RPD), in cases where fixed solutions cannot be considered, poses various challenges inherent in the mixed support of the prosthesis, especially when the edentulism is of a large extent. When an implant is placed to assist a removable denture, it allows ensuring a bio-functional, aesthetic, and comfortable rehabilitation. Additionally, it renders possible resolutions to problems related to conventional RPD.
View Article and Find Full Text PDFBMC Oral Health
September 2024
State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan, PR China.
Background: Failure to restore missing teeth in time can easily lead to the mesial tilting of the distal abutment teeth. However, a fixed partial denture (FPD) can improve stress conduction and distribution and prevent periodontal injuries. In these more complex cases, it is necessary to consider various factors comprehensively to improve conventional treatment planning and achieve better results.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!