Purpose: To evaluate the efficacy and safety of transvenous coil embolization of the venous sac for type II renal arteriovenous malformation (AVM).
Materials And Methods: A retrospective review was conducted of 8 patients (5 women and 3 men; mean age, 57 years; age range, 41-69 years) who underwent transvenous coil embolization for type II congenital renal AVM at 5 different hospitals between 2012 and 2018. Additional intra-arterial ethanol injection was performed if shunt flow persisted after venous sac coiling. Technical success was defined as complete occlusion of shunt flow with coil embolization. Clinical success was defined as no symptom recurrence during the follow-up period. The renal parenchymal infarction rate was measured on computed tomography (CT), and procedure-related complications were reviewed.
Results: Nine sessions of embolization were performed for 8 patients. The mean venous sac size was 24 mm (range, 10-39 mm), and a mean of 14 micro and/or micro-detachable coils (range, 3-50) were used. The technical success rate was 88% (7 of 8) using coil embolization. One patient (12%) required additional ethanol injection to complete occlusion of the shunt flow and had a less than 10% parenchymal infarction on follow-up CT. No procedure-related complications or recurrences occurred during a mean clinical follow-up period of 20.8 months (range, 4.7-76.6 months).
Conclusions: Transvenous coil embolization of type II renal AVM showed an 88% technical success rate. One patient (12%) showed less than 10% renal parenchymal infarction after additional ethanol injection. No additional complications or recurrences occurred during the follow-up period.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jvir.2018.09.019 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!