A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 143

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 980
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3077
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The Outcomes Assessment of the Plasma Blade Technology in Upper Blepharoplasties: A Prospective Study on a Series of 25 Patients. | LitMetric

The Outcomes Assessment of the Plasma Blade Technology in Upper Blepharoplasties: A Prospective Study on a Series of 25 Patients.

Aesthetic Plast Surg

Department of Plastic, Reconstructive, Aesthetic and Maxillofacial Surgery, Henri Mondor Hospital, 51 Avenue du Maréchal de Lattre de Tassigny, 94010, Créteil, France.

Published: August 2019

Background: The Dermo Ablation Surgery (DAS) Medical® (Technolux, Italy) device is a plasma blade which induces a plasma voltaic arc causing a retraction in the epidermis and superficial dermis.

Objective: The aim of our study is to prove the efficacy and safety of the DAS Medical® device in dermatochalasis size reduction.

Methods: Our prospective study included 25 adult patients presenting with upper eyelid dermatochalasis undergoing a two-session treatment protocol with the DAS Medical® device (with a month treatment-free interval). The primary end point was the reduction in the size of the dermatochalasis. The secondary end points were patient satisfaction, and a blinded assessment of the outcomes was carried out by 15 plastic surgery specialists on post-procedural pictures.

Results: The mean reduction in the size of the dermatochalasis was estimated at 2.47 mm on a 6-month follow-up (13.5 mm at T0 vs. 11.03 mm at 6 months, p = 0.0002) and 1.97 mm on a 12-month follow-up ((13.5 mm at T0 vs. 11.53 mm at 12 months, p = 0.0055). Eighty per cent of the patients and 78% of the assessing clinicians were globally satisfied with the results on a 12-month follow-up. The mean visual analogue pain score reported during the treatment was 4.5/10; MEOPA® was used in 23% of cases. No irreversible post-procedural sequelae (complications) were observed.

Conclusion: Voltaic plasma arc treatment with DAS Medical® is an effective technique for non-invasive blepharoplasty on moderate dermatochalasis patients not suffering from palpebral lipoptosis and is very well tolerated. It can be usefully and successfully associated with surgery.

Level Of Evidence Iv: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00266-019-01360-2DOI Listing

Publication Analysis

Top Keywords

das medical®
16
plasma blade
8
prospective study
8
medical® device
8
reduction size
8
size dermatochalasis
8
follow-up 135 mm
8
12-month follow-up
8
dermatochalasis
5
outcomes assessment
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!