A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Legionella pneumophila levels and sequence-type distribution in hospital hot water samples from faucets to connecting pipes. | LitMetric

AI Article Synopsis

  • Recent research indicates that Legionella pneumophila (Lp) levels are higher at faucets in hot water systems than in main supply lines, suggesting environmental factors may influence this.
  • This study examined Lp concentrations in a hospital’s hot water system, comparing samples from faucets and upstream pipes before and after temperature adjustments.
  • Out of 47 isolates from positive samples, two sequence types (STs) were identified, with ST378 predominating, indicating low genetic diversity and potential adaptation strategies within the system.

Article Abstract

Recent studies have reported increased levels of Legionella pneumophila (Lp) at points of use compared to levels in primary and secondary components of hot water systems, suggesting possible selection by environmental conditions. In this study, concentrations of Lp in a hospital hot water system were evaluated by profile sampling, collecting successive water samples to determine the prevalence at the faucet (distal) and upstream piping before and after a system intervention to increase temperature. Lp strain diversity was compared between different points of use and different areas of the hot water system (i.e., tap, intermediate piping and main upflow piping). In total, 47 isolates were recovered from 32 positive hot water samples collected from designated taps, showers and recirculation loops; these isolates were subsequently analyzed by sequence-based typing (SBT). Lp levels were comparable between first draw (500 mL) and flushed (2 and 5 min) samples, whereas a decrease was observed in the amount of culturable cells (1 log). Two sequence types (STs) were identified throughout the system. ST378 (sg4/10) was present in 91% of samples, while ST154-like (sg1) was present in 41%; both STs were simultaneously recovered in 34% of samples. Isolated STs displayed comparable tolerance to copper (0.8-5 mg/L) and temperature (55 °C, 1 h) exposure. The ability to replicate within THP1 cells and Acanthamoeba castellanii was similar between the two STs and a comparative environmental outbreak strain. The low Lp diversity and the detection of both Lp sequence types in repeated subsequent samples collected from positive faucets in a hospital wing suggest a minimal impact of the distal conditions on strain selection for the sampled points, as well as a possible adaptation to stressors present in the system, leading to the predominance of a few strains.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.watres.2019.03.019DOI Listing

Publication Analysis

Top Keywords

hot water
20
water samples
12
legionella pneumophila
8
hospital hot
8
water system
8
samples collected
8
sequence types
8
samples
7
water
6
hot
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!