BACKGROUND In the present study, we aimed to determine the effect of different positive end-expiratory pressure (PEEP) levels on the cross-sectional area (CSA) of the right internal jugular vein (RIJV) and the overlap index between the RIJV and the right common carotid artery (RCCA) in mechanically ventilated patients with laryngeal mask airway (LMA) insertion. MATERIAL AND METHODS A total of 60 patients who were scheduled for elective surgery under general anesthesia with LMA insertion were enrolled. After LMA insertion, the image of RIJV and RCCA were taken after applying 4 different PEEPs in a random order: 0 (P0), 5 (P5), 10 (P10), and 15 (P15) cm H₂O. The CSA, transverse and anteroposterior (AP) diameters of the RIJV, and the overlap index were measured. RESULTS Compared to group P0, the overlap indexes of P10 (P=0.0032) and P15 (P<0.001) were significantly increased, but without a significant trend toward further increases in group P15. PEEP at 10 and 15 cm H₂O increased CSA, transverse and AP diameter of the RIJV in comparison to group P0 (all P<0.001). There was a statistically significant increase in CSA of the RIJV in P15 compared with P10 by 12.2% (P<0.001), but did not reach the relevant cut-off value (ΔCSA ≥15%). CONCLUSIONS The application of PEEP at 10 cm and 15 cm H₂O in patients receiving mechanical ventilation with LMA insertion significantly increases the size of the RIJV. However, the overlap index between the RIJV and the RCCA increased as well.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6451356 | PMC |
http://dx.doi.org/10.12659/MSM.913595 | DOI Listing |
Front Med (Lausanne)
December 2024
Department of Anaesthesiology and Intensive Therapy, Medical University of Lodz, Łódź, Poland.
Background: The Laryngeal Mask Airway Vision Mask (LMA VM) is a supraglottic airway device (SAD) with a vision guidance system. The ideal head and neck position for direct laryngoscopy is known, but the ideal position for placing a LMA is not. The objective of this study is to evaluate and compare the optimal position for placement of a video laryngeal mask airway.
View Article and Find Full Text PDFBMC Anesthesiol
December 2024
Department of Anesthesiology, The Second Clinical Medical College, North Sichuan Medical College, Nanchong Central Hospital, Nanchong, China.
Background: Ciprofol, a novel intravenous anesthetic, exhibits similar sedation mechanisms and pharmacokinetic properties to propofol. However, ciprofol demonstrates greater potency and is associated with reduced injection pain compared to propofol. Given the varying sensitivities to anesthetic agents across different age groups, this study aims to determine the median effective dose (ED) of ciprofol required to suppress the laryngeal mask airway (LMA) insertion response in both young and older adult patients, as well as to assess its potential adverse reactions.
View Article and Find Full Text PDFIndian J Anaesth
October 2024
Department of Anaesthesiology, Government Medical College, Pali, Rajasthan, India.
Br J Anaesth
December 2024
Washington University in Saint Louis, Anaesthesiology Barnes Jewish Hospital, Saint Louis, MO, USA. Electronic address:
Background: Over the last two decades, significant research interest has led to the development of a wide variety of supraglottic airways (SGAs) for anaesthesia providers to choose from.
Methods: In this network meta-analysis, we analysed 111 studies, enrolling 12 045 patients undergoing airway management with 29 SGAs. We targeted outcomes that contribute to clinicians' choice of one SGA over another.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!