Artificial turf advances have enabled surfaces to behave like natural grass, however, debate remains as to whether artificial turf is as safe as natural grass. To reduce injury risk, sport surfaces should have low rotational traction with artificial surfaces having a potential advantage as components can be manipulated to change surface properties and traction. The purpose of this study was to investigate the influence that different components of artificial turf have on rotational traction and athlete lower extremity joint loading. Twelve surfaces underwent mechanical testing to determine the influence of fibre density, fibre length, infill composition and compaction on rotational traction. Following mechanical testing, Control, Low and High Traction surfaces were selected for biomechanical analysis, where sixteen athletes performed maximum effort v-cuts while kinematic/kinetic data were recorded on each surface. Mechanically, fibre density, type of infill and compaction of the surface each independently influenced traction. The traction differences were substantial enough to alter the athlete kinematics and kinetics. Low traction surfaces reduced ankle and knee loading, while high traction surfaces increased ankle and knee loading . Reducing the rotational traction of sport surfaces is possible through alterations of individual components, which may reduce the joint loading at the knee and ankle joint.

Download full-text PDF

Source
http://dx.doi.org/10.1080/02640414.2019.1598923DOI Listing

Publication Analysis

Top Keywords

rotational traction
20
artificial turf
16
traction surfaces
12
traction
11
turf rotational
8
traction athlete
8
surfaces
8
natural grass
8
sport surfaces
8
joint loading
8

Similar Publications

This report presents the case of a seven-year-old child diagnosed with Grisel's syndrome following a craniotomy for a cystic brain lesion. The patient initially presented with persistent, progressively worsening headaches that coincided with neurological symptoms. Imaging revealed a massive cystic lesion causing a significant compression and midline shift.

View Article and Find Full Text PDF

A Novel Detection Scheme for Motor Bearing Structure Defects in a High-Speed Train Using Stator Current.

Sensors (Basel)

November 2024

Technology and Equipment of Rail Transit Operation and Maintenance Key Laboratory of Sichuan Province, Chengdu 610031, China.

Railway traction motor bearings (RTMB) are critical components in high-speed trains (HST) that are particularly susceptible to failure due to the high stress and rotational frequency they experience. To address the challenge of high false-positive rates in existing monitoring systems, this paper introduces a novel sensorless monitoring scheme that leverages stator current to detect fault-related characteristics, eliminating the need for additional sensors. This approach employs a hybrid signal preprocessing algorithm that integrates adaptive notch filtering (ANF) with envelope spectrum analysis (ESA) to effectively sparse the stator current and extract relevant fault features.

View Article and Find Full Text PDF

Torticollis in incomplete Kawasaki disease: a case of atlantoaxial rotatory fixation.

BJR Case Rep

November 2024

Department of Orthopaedic Surgery, Tokyo Metropolitan Toshima Hospital, Tokyo 173-0015, Japan.

Various respiratory, musculoskeletal, gastrointestinal, neurological, and urinary complications have been reported in Kawasaki disease. Here, we describe a rare case of atlantoaxial rotatory fixation (AARF) associated with incomplete Kawasaki disease. The case is of a healthy 4-year-old Japanese boy who had a high-grade fever, lymphadenopathy, and torticollis diagnosed with incomplete Kawasaki disease.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!