Background: Fluoroscopic imaging guidance is frequently used in performing spinal interventional techniques. Reference level standards are a quality improvement tool to help reduce radiation dose and serve as benchmarks for physicians and their technologists to achieve reasonable radiation exposure while performing fluoroscopically-guided spinal procedures. There are limited data describing radiation dose for musculoskeletal injections - in particular, spinal injections without any published reference standards.
Objective: The purpose of this study is to perform a practice audit of radiation doses of fluoroscopically-guided spinal injections to establish preliminary reference levels as a quality improvement tool for potential use in future radiation reduction measures.
Study Design: Retrospective, observational study.
Settings: An academic-based subspecialty, high volume pain medicine practice.
Methods: A retrospective analysis of 6,234 spinal injections of 9 different types performed by experienced practitioners between January and December 2012 was conducted under an institutional review board's approval with HIPAA compliance and waiver of informed consent. Cumulative radiation dose (in mGy) and exposure time (in seconds) distributions (percentiles) as displayed on the C-arm were calculated per injection for each type of fluoroscopically-guided spinal injection. Confidence intervals for the dose distributions were determined by using bootstrap resampling and were used to determine preliminary reference levels.
Results: Proposed preliminary reference levels of cumulative radiation dose (in mGy) and exposure time (in seconds) for fluoroscopically-guided spinal interventional procedures are provided for lumbar transforaminal (13 mGy, 30 s), cervical transforaminal (6 mGy, 49 s), caudal epidural (12 mGy, 23s), cervical facet injection (3 mGy, 36 s), lumbar facet injection (9 mGy, 20s), interlaminar (13mGy, 39s), lumbar radiofrequency denervation (7 mGy, 17s), lumbar sympathetic block (21 mGy, 39s), cervical medial branch block (2 mGy, 25 s), lumbar medial branch block (4 mGy, 12s) and sacroiliac joint injections (18 mGy, 37s).
Limitations: Study performed at a single subspecialty institution using only one type of C-arm which limits generalizability.
Conclusions: Radiation doses and preliminary reference levels of fluoroscopically-guided interventional spine procedures performed by experienced practitioners are made available without correction for body habitus or field of view, magnification or subtraction techniques or continuous vs pulsed mode. A registry of radiation-dose data for fluoroscopically-guided interventional spine procedures would be the next step to refine this data.
Key Words: Spinal procedures, radiation dose, patient safety.
Download full-text PDF |
Source |
---|
Biomed Phys Eng Express
January 2025
Mindanao Radiation Physics Center, MSU-Iligan Institute of Technology, Andres Bonifacio Street Tibanga, Iligan City, Lanao Norte, 9200, PHILIPPINES.
To accurately model and validate the 6 MV Elekta Compactlinear accelerator using the Geant4 Application for Tomographic Emission (GATE). In particular, this study focuses on the precise calibration and validation of critical parameters, including jaw collimator positioning, electron source nominal energy, flattening filter geometry, and electron source spot size, which are often not provided in technical documentation. Methods: Simulation of the Elekta Compact6 MV linear accelerator was performed using the Geant4 Application for Tomographic Emission (GATE) v.
View Article and Find Full Text PDFNeurosurgery
September 2024
Department of Surgery, Division of Neurosurgery, Centre de recherche du Centre Hospitalier Universitaire de Sherbrooke, Université de Sherbrooke, Sherbrooke, Québec, Canada.
Background And Objectives: Oligodendrogliomas are primary brain tumors classified as isocitrate deshydrogenase-mutant and 1p19q codeleted in the 2021 World Health Organization Classification of central nervous system tumors. Surgical resection, radiotherapy, and chemotherapy are well-established management options for these tumors. Few studies have evaluated the efficacy of stereotactic radiosurgery (SRS) for oligodendroglioma.
View Article and Find Full Text PDFSupport Care Cancer
January 2025
Oral Diagnosis Department, Faculdade de Odontolodia de Piracicaba, Universidade de Campinas (UNICAMP), Piracicaba, São Paulo, Brazil.
Purpose: Oral mucositis (OM) reflects a complex interplay of several risk factors. Machine learning (ML) is a promising frontier in science, capable of processing dense information. This study aims to assess the performance of ML in predicting OM risk in patients undergoing head and neck radiotherapy.
View Article and Find Full Text PDFPediatr Radiol
January 2025
Boston Children's Hospital, 300 Longwood Avenue, Boston, MA, 02115, USA.
Background: Radiographic skeletal survey plays an important role in the diagnosis of infant abuse. Some practitioners have expressed concerns about the radiation exposure from this examination.
Objective: To utilize state-of-the-art hybrid computational phantoms to more accurately estimate radiation doses of skeletal surveys performed for suspected infant abuse.
Ann Surg Oncol
January 2025
Section of Plastic and Reconstructive Surgery, Department of Surgery, University of Michigan Health Systems, Ann Arbor, MI, USA.
Background: The placement of breast implants in a prepectoral plane has become increasingly popular in breast reconstruction, although data on how this affects radiation delivery in women with breast cancer are limited. This study aimed to assess the dosimetric differences in radiation plans for immediate breast reconstruction between prepectoral and subpectoral implants.
Methods: In this study, a retrospective review and dosimetric analysis of patients with breast cancer who underwent immediate implant-based reconstruction and postmastectomy radiation therapy (PMRT) were performed.