σ-Holes and Si···N intramolecular interactions.

J Mol Model

Department of Chemistry, University of New Orleans, New Orleans, LA, 70148, USA.

Published: March 2019

We report a computational study of two series of molecules, one having the Si-O-N linkage and the other with the Si-(CH)-N linkage, where n = 1-4. The silicons have various substituents-combinations of H, CH, F, Cl and CF. Many of these compounds have been prepared and characterized experimentally. The Si···N distances were found to be relatively short, which may denote a noncovalent interaction or may simply be dictated by the molecular structures. This and the nature of the interaction (if any) were the subjects of our study. We addressed these issues computationally, determining optimized geometries, energies and electrostatic potentials at the density functional M06-2X/6-31 + G(d,p) level. We conclude that there is an attractive Coulombic Si···N interaction in each case, although it is sometimes quite weak. It involves the lone pair of the nitrogen and the positive σ-hole potential produced on the silicon by the bonding from the substituent that is anti to the nitrogen. This accounts for the key features of these molecules, such as the dependence of the Si···N distances upon the electron-withdrawing power of the anti substituent and the effects of gauche chlorines in weakening the interactions. When the Si···N interactions are disrupted by rotation of the N(CH) group or by conversion of the molecules to open-chain conformers, the Si···N distances lengthen and are essentially the same regardless of the substituent in the anti position. These observations confirm the presence of Si···N interactions in the original molecules.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00894-019-3962-2DOI Listing

Publication Analysis

Top Keywords

si···n distances
12
substituent anti
8
si···n interactions
8
si···n
6
σ-holes si···n
4
si···n intramolecular
4
interactions
4
intramolecular interactions
4
interactions report
4
report computational
4

Similar Publications

A Descriptive Analysis of the Seasonal Patterns of Bone Stress Injury Incidence in Division I Collegiate Distance Runners.

Am J Sports Med

January 2025

Department of Orthopaedic Surgery, Division of Physical Medicine and Rehabilitation, Stanford University, Stanford, California, USA.

Background: A bone stress injury (BSI) is a common overuse injury in collegiate athletes, particularly cross-country and track and field runners. Limited work describes the seasonality of BSIs or the differences in rates and anatomic locations of BSIs in collegiate runners.

Purpose: To describe seasonally related trends in anatomic locations of BSIs in National Collegiate Athletic Association (NCAA) Division I male and female middle- and long-distance runners.

View Article and Find Full Text PDF

Purpose: To analyse anterior segment optical coherence tomography (AS-OCT) parameters of graft dehiscence after Descemet membrane endothelial keratoplasty (DMEK) for graft failure post penetrating keratoplasty (PK).

Methods: Retrospective evaluation of AS-OCT images of 142 dehiscences post-DMEK in 75 eyes. Dehiscences' size, depth, location, correlation with graft-host interface (GHI) override and step at GHI were assessed.

View Article and Find Full Text PDF

Theorists across all fields of psychology consider goals crucial for human action control. Still, the question of how precisely goals are represented in the cognitive system is rarely addressed. Here, we explore the idea that goals are represented as distributed patterns of activation that coexist within continuous mental spaces.

View Article and Find Full Text PDF

In this research, a green approach utilizing deep eutectic solvent liquid-liquid microextraction is combined with smartphone digital image colorimetry for the determination of boron in nut samples. A smartphone camera was used to capture the image of the analyte extract located in a custom-made colorimetric box. Using ImageJ software, the images were split into RGB channels, with the green channel identified as the optimum.

View Article and Find Full Text PDF

The duration of mechanical systole-also termed the flow time (FT) or left ventricular ejection time (LVET)-is measured by Doppler ultrasound and increasingly used as a stroke volume (SV) surrogate to guide patient care. Nevertheless, confusion exists as to the determinants of FT and a critical evaluation of this measure is needed. Using Doppler ultrasound of the left ventricular outflow tract velocity time integral (LVOT VTI) as well as strain and strain rate echocardiography as grounding principles, this brief commentary offers a model for the independent influences of FT.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!