A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Factors Associated With High-Voltage Impedance and Subcutaneous Implantable Defibrillator Ventricular Fibrillation Conversion Success. | LitMetric

Background: The ability to predict defibrillation efficacy at the time of subcutaneous implantable cardioverter-defibrillator implantation without the need to induce ventricular fibrillation might eliminate the need for defibrillation testing. The purpose of this study was to determine the association of high-voltage impedance and system implant position on ventricular fibrillation conversion success with a submaximal 65-J shock.

Methods: In the subcutaneous implantable cardioverter-defibrillator IDE study (Investigational Device Exemption), a successful conversion test required 2 consecutive ventricular fibrillation conversions at 65 J in either shock vector. Chest radiographs were obtained after implantation. Patients with imaging and impedance data were included. Suboptimal device position was defined as an inferior electrode or pulse generator or electrode coil depth >3 mm anterior to the sternum. Absence of suboptimal positional parameters was defined as appropriate position. Conversion success rate was calculated among all 65-J tests.

Results: Of 314 patients who underwent subcutaneous implantable cardioverter-defibrillator implantation, 282 patients were included in this analysis. There were 637 inductions to test defibrillation at 65 J. Sixty-two conversion failures (9.7%) occurred in 42 (14.9%) patients. Lower body mass index and lower shock impedance were associated with higher conversion success rate, whereas white race was associated with lower conversion success rate. Suboptimal position was more common in obese patients. Inferior electrode and greater distance between the lead and sternum were associated with a higher impedance. When appropriate system position was achieved, conversion failure was not associated with high body mass index.

Conclusions: Subcutaneous implantable cardioverter-defibrillator shock efficacy is associated with system position and high-voltage system impedance. A high impedance is associated with inferiorly placed pulse generator and electrode system, inadequate coil depth, and a lower rate of defibrillator success.

Clinical Trial Registration: URL: https://www.clinicaltrials.gov . Unique identifier: NCT01064076.

Download full-text PDF

Source
http://dx.doi.org/10.1161/CIRCEP.118.006665DOI Listing

Publication Analysis

Top Keywords

subcutaneous implantable
20
conversion success
20
ventricular fibrillation
16
implantable cardioverter-defibrillator
16
success rate
12
high-voltage impedance
8
conversion
8
fibrillation conversion
8
cardioverter-defibrillator implantation
8
inferior electrode
8