The purpose of this study is to determine whether iodine quantification techniques from contrast-enhanced dual-energy CT (DECT) data allow equal differentiation of small enhancing renal masses from high-attenuation (> 20 HU of unenhanced attenuation) nonenhancing lesions, compared with conventional attenuation measurements. A total of 220 nonconsecutive patients (mean [± SD] age, 66 ± 13 years; 130 men and 90 women) with 265 high-attenuation renal lesions (mean attenuation, 54 ± 33 HU; 91 enhancing lesions) were included. Each patient underwent single-energy unenhanced CT followed by DECT during the nephrographic phase using one of four different high-end DECT platforms (first- and second-generation rapid-kilovoltage-switching DECT platforms and second- and third-generation dual-source DECT platforms). Iodine quantification measurements and conventional attenuation change measurements were calculated for each lesion. Diagnostic accuracy was determined by pathologic analysis, confirmation with another imaging modality, or greater than 24 months of imaging follow-up as the reference standard. The diagnostic accuracy for differentiating enhancing from nonenhancing renal lesions was significantly higher for conventional attenuation change measurements, compared with iodine quantification measurements (AUC values, 0.973 vs 0.875; < 0.0001). The diagnostic performance of iodine quantification measurements improved only marginally with the utilization of DECT platform-specific optimized iodine quantification thresholds, yielding AUC values of 0.907 and 0.893 for the rapid-kilovoltage-switching DECT and dual-source DECT platforms, respectively. Unenhanced lesion attenuation ( = 0.0010) and intraparenchymal location ( = 0.0249) significantly influenced the diagnostic accuracy of the iodine quantification techniques. Iodine quantification from DECT data yields inferior diagnostic accuracy when compared with conventional attenuation change measurements for differentiating small, truly enhancing renal masses and high-attenuation renal lesions.

Download full-text PDF

Source
http://dx.doi.org/10.2214/AJR.18.20547DOI Listing

Publication Analysis

Top Keywords

iodine quantification
32
conventional attenuation
20
renal lesions
16
dect platforms
16
diagnostic accuracy
16
small enhancing
12
enhancing renal
12
renal masses
12
masses high-attenuation
12
quantification measurements
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!