A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Coupling Musculoskeletal Dynamics and Subject-Specific Finite Element Analysis of Femoral Cortical Bone Failure after Endoprosthetic Knee Replacement. | LitMetric

Background And Objective: A common reconstruction procedure after a wide resection of bone tumors around the knee is endoprosthetic knee replacement. The aim of this study was to investigate the characteristics of bone injury of the patient after endoprosthetic knee replacement during walking.

Methods: A subject-specific finite element model of the femur-prosthesis-tibia complex was established via CT scans. To obtain its physiologically realistic loading environments, the musculoskeletal inverse dynamic analysis was implemented. The extracted muscle forces and ground forces were then applied to the finite element model to investigate bone stress distribution at various stages of the gait cycle.

Results: The maximum femur stress of each stage varied from 33.14 MPa to 70.61 MPa in the gait cycle. The stress concentration position with a distance of 267.2 mm to the tibial plateau showed a good agreement with the patient injury data.

Conclusions: Overall results indicated the reasonability of the simulation method to determine loading environments and injury characteristics which the patient experienced with knee endoprosthesis during walking.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6402239PMC
http://dx.doi.org/10.1155/2019/4650405DOI Listing

Publication Analysis

Top Keywords

finite element
12
endoprosthetic knee
12
knee replacement
12
subject-specific finite
8
element model
8
loading environments
8
knee
5
coupling musculoskeletal
4
musculoskeletal dynamics
4
dynamics subject-specific
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!