Background: Sweat, as an easily accessible bodily fluid, is enriched with a lot of physiological and health information. A portable and wearable sweat sensor is an important device for an on-body health monitoring. However, there are only few such devices to monitor sweat. Based on the fact that sweat is mainly composed of moisture and salt which is much more abundant than other trace ions in sweat, a new route is proposed to realize wearable sweat sensors using CdSSe nanowire-chips coated with a polyimide (PI) membrane.
Results: Firstly, the composition-graded CdSSe (x = 0-1) nanowire-chip based sensor shows good photo-sensitivity and stress sensitivity which induces linear humidity dependent conductivity. This indicates good moisture response with a maximum responsivity (dI/I) 244% at 80% relative humidity (RH) even in the dark. Furthermore, the linear current decrease with salt increase illustrates the chip sensor has a good salt-sensing ability with the best salt dependent responsivity of 80%, which guarantees the high prediction accuracy in sweat sensing. The sensor current is further proven to nonlinearly correlate to the amount of sweat with excellent stability, reproducibility and recoverability. The wearable sweat sensor is finally applied on-body real-time sweat analysis, showing good consistence with the body status during indoor exercise.
Conclusions: These results suggest that this CdSSe nanowire-chip based PI-coated integrated sensor, combined with inorganic and organic functional layers, provides a simple and reliable method to build up diverse portable and wearable devices for the applications on healthcare and athletic status.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6434865 | PMC |
http://dx.doi.org/10.1186/s12951-019-0480-4 | DOI Listing |
Biosens Bioelectron
January 2025
Jiangsu Key Laboratory of Advanced Catalytic Materials and Technology, School of Petrochemical Engineering, Changzhou University, 213164, Changzhou, China. Electronic address:
Wearable sensors can easily enable real-time and noninvasive glucose (Glu) monitoring, providing vital information for effectively preventing various complications caused by high glucose level. Here, a wearable sensor based on nanozyme-catalyzed cascade reactions is designed for Glu monitoring in sweat. Au nanoparticles (AuNPs) are anchored to the carbonated zeolitic imidazolate framework-8 (ZIF-8-C), endowing the sensor with Glu oxidase (GOx)-like and peroxidase (POD)-like activity.
View Article and Find Full Text PDFACS Appl Bio Mater
January 2025
Department of Medical Devices, National Institute of Pharmaceutical Education and Research, Guwahati, Assam 781101, India.
Using a laser-scribed (direct printing) technique, we have fabricated an enzymeless, mediatorless, and paper-interfaced electrochemical device (P-LSG) for uric acid detection on a flexible polyimide sheet. Various paper substrates were investigated, and it was found that Whatman filter paper-1 is promising to obtain the best electrochemical signals at the small volume of electrolyte, i.e.
View Article and Find Full Text PDFSmall
January 2025
School of Materials & Energy, Southwest University, Chongqing, 400715, P. R. China.
1D moisture-enabled electric generators (MEGs) hold great promise for powering electronic textiles, but their current limitations in power output and operational duration restrict their application in wearable technology. This study introduces a high-performance yarn-based moisture-enabled electric generator (YMEG), which comprises a carbon-fiber core, a cotton yarn active layer with a radial gradient of poly(4-styrensulfonic acid) and poly(vinyl alcohol) (PSSA/PVA), and an aluminum wire as the outer electrode. The unique design maintains a persistent moisture gradient between the interior and exterior electrodes, enhancing performance through the continuous proton diffusion from PSSA and Al⁺ ions from the aluminum wire.
View Article and Find Full Text PDFACS Sens
January 2025
School of Materials Science and Engineering, Guangzhou Key Laboratory of Flexible Electronic Materials and Wearable Devices, Key Laboratory for Polymeric Composite and Functional Materials of Ministry of Education, State Key Laboratory of Optoelectronic Materials and Technologies, Sun Yat-sen University, Guangzhou 510275, People's Republic of China.
Steroid hormones, especially progesterone (P), estradiol (E), and testosterone (T), are key bioactive regulators in various female physiological processes, including growth and development, ovulation, and the reproductive cycle, as well as metabolism and mental health. As lipophilic molecules produced in sex glands, these steroid female hormones can be transported through blood vessels into various body fluids such as saliva, sweat, and urine. However, the ultralow concentration of steroid hormones down to picomolar (pM) level necessitates great demands for ultrasensitive but low-cost analytic tools to implement accurate, point-of-care or even continuous monitoring in a user-friendly fashion.
View Article and Find Full Text PDFJ Chromatogr B Analyt Technol Biomed Life Sci
December 2024
Clinical Laboratory, Catharina Hospital Eindhoven, Eindhoven 5623 EJ, The Netherlands; Department of Biomedical Engineering, Chemical Biology, Eindhoven University of Technology, Groene Loper 3, Eindhoven 5612 AE, The Netherlands.
Monitoring of kidney function traditionally relies on plasma creatinine concentrations, necessitating invasive blood draws. Non-invasively obtainable biofluids, such as sweat and saliva, present a patient-friendly alternative with potential for continuous monitoring. This study focusses on developing and validating a novel Liquid Chromatography- tandem Mass Spectrometry (LC-MS/MS) assay as a reference test for measuring low creatinine concentrations in sweat and saliva.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!