A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A smartphone fluorescence imaging-based mobile biosensing system integrated with a passive fluidic control cartridge for minimal user intervention and high accuracy. | LitMetric

A key challenge for realizing mobile device-based on-the-spot environmental biodetection is that a biosensor integrated with a fluid handling sensor cartridge must have acceptable accuracy comparable to that of conventional standard analytical methods. Furthermore, the user interface must be easy to operate, technologically plausible, and concise. Herein, we introduced an advanced smartphone imaging-based fluorescence microscope designed for Hg2+ monitoring by utilizing a biosensor cartridge that reduced user intervention via time-sequenced passive fluid handling. The cartridge also employed a metal-nanostructured plastic substrate for complementing the fluorescence signal output; this helped the realization of high-accuracy detection, in which a ratiometric dual-wavelength detection method was applied. Using 30 samples of Hg2+-spiked wastewater, we showed that our device, which has a detection limit of ∼1 pM, can perform analytical assays accurately. The detection results from our method were in good linearity and agreement with those of conventional standard methods. We conclude that the integration of a simple-to-use biosensor cartridge, fluorescence signal-enhancing substrate, dual-wavelength detection, and quantitative image data processing on a smartphone has great potential to make any population accessible to small-molecule detection, which has been performed in centralized laboratories for environmental monitoring.

Download full-text PDF

Source
http://dx.doi.org/10.1039/c8lc01344fDOI Listing

Publication Analysis

Top Keywords

user intervention
8
fluid handling
8
conventional standard
8
biosensor cartridge
8
dual-wavelength detection
8
detection method
8
detection
6
cartridge
5
smartphone fluorescence
4
fluorescence imaging-based
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!