Background: It is not established beyond doubt whether improvements in functional outcome after total knee arthroplasty (TKA) are maintained in the long term. We therefore investigated the temporal patterns of functional outcome [using range of motion (ROM), American Knee Society (AKS) score, Western Ontario and McMaster Universities Arthritis Index (WOMAC) score, and 36-Item Short Form Health Survey (SF-36) score] over a 5-year period after uncomplicated TKA, and whether these patterns differed by implant type and patient age.
Materials And Methods: This prospective study evaluated 138 patients who underwent unilateral TKA with either a mobile-bearing (MB) or fixed-bearing (FB) posterior-stabilized prosthesis. An independent investigator evaluated the functional outcome at five time points: preoperatively and at 6-month, 1-year, 2-year, and 5-year follow-up. Differences in functional outcomes between adjacent time points were evaluated by mixed-effect model repeat measurement (MMRM).
Results: The different functional outcome scores showed improvement till 6 months-2 years, followed by a variable decline. In patients aged ≥ 68 years with an MB implant, most of the functional outcome scores declined between 2 and 5 years after variable initial improvement till 6 months-2 years, whereas the parameters plateaued after 2 years in those aged < 68 years and in older patients with an FB implant.
Conclusions: A decline in function and pain relief occurs 2 years after TKA. This decline is more evident in older patients with an MB prosthesis. Based on these findings, we believe that use of MB implants in older patients (≥ 68 years) requires further investigation.
Level Of Evidence: Level 3.