Increasing spatial and temporal resolutions of functional MRI (fMRI) measurement has been shown to benefit the study of neural dynamics and functional interaction. However, acceleration of rodent brain fMRI using parallel and simultaneous multi-slice imaging techniques is hampered by the lack of high-density phased-array coils for the small brain. To overcome this limitation, we adapted phase-offset multiplanar and blipped-controlled aliasing echo planar imaging (EPI) to enable simultaneous multi-slice fMRI of the mouse brain using a single loop coil on a 9.4T scanner. Four slice bands of 0.3 × 0.3 × 0.5 mm resolution can be simultaneously acquired to cover the whole brain at a temporal resolution of 300 ms or the whole cerebrum in 150 ms. Instead of losing signal-to-noise ratio (SNR), both spatial and temporal SNR can be increased due to the increased k-space sampling compared to a standard single-band EPI. Task fMRI using a visual stimulation shows close to 80% increase of z-score and 4 times increase of activated area in the visual cortex using the multiband EPI due to the highly increased temporal samples. Resting-state fMRI shows reliable detection of bilateral connectivity by both single-band and multiband EPI, but no significant difference was found. Without the need of a dedicated hardware, we have demonstrated a practical method that can enable unparallelly fast whole-brain fMRI for preclinical studies. This technique can be used to increase sensitivity, distinguish transient response or acquire high spatiotemporal resolution fMRI.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.neuroimage.2019.03.045 | DOI Listing |
Dentomaxillofac Radiol
January 2025
Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100730, China.
Objectives: To compare integrated slice-specific dynamic shimming (iShim) and simultaneous multi-slice (SMS) readout-segmented echo-planar imaging (RESOLVE) for diffusion-weighted imaging (DWI) of malignant head and neck tumours.
Methods: In this prospective study, 45 patients with malignant head and neck lesions underwent iShim- and SMS-RESOLVE imaging with two b-values (0, 800 s/mm2) at 3 T. Subjective image quality scores (lesion distortion, signal loss, fat saturation, and artefacts), quantitative lesion distortion, quantitative image quality [signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and SNR efficiency], ADC values, and total acquisition times of iShim- and SMS-RESOLVE imaging were evaluated and compared.
J Magn Reson Imaging
December 2024
Utah Center for Advanced Imaging Research (UCAIR), Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, USA.
Background: Modified Look-Locker imaging (MOLLI) T1 mapping sequences are acquired during breath-holding and require ECG gating with consistent R-R intervals, which is problematic for patients with atrial fibrillation (AF). Consequently, there is a need for a free-breathing and ungated framework for cardiac T1 mapping.
Purpose: To develop and evaluate a free-breathing ungated radial simultaneous multi-slice (SMS) cardiac T1 mapping (FURST) framework.
Cureus
November 2024
Department of Joint Research in Advanced Medicine for Electromagnetic Engineering, Shimane University, Izumo, JPN.
Magn Reson Med
November 2024
Ming Hsieh Department of Electrical and Computer Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California, USA.
Purpose: To determine the feasibility of simultaneous multi-slice (SMS) real-time MRI (RT-MRI) at 0.55T for the evaluation of cardiac function.
Methods: Cardiac CINE MRI is routinely used to evaluate left-ventricular (LV) function.
Hum Brain Mapp
November 2024
Department of Biomedical Engineering, Stony Brook University, Stony Brook, New York, USA.