Ultrafast fMRI of the rodent brain using simultaneous multi-slice EPI.

Neuroimage

Queensland Brain Institute, The University of Queensland, Brisbane, Australia; Centre of Advanced Imaging, The University of Queensland, Brisbane, Australia. Electronic address:

Published: July 2019

Increasing spatial and temporal resolutions of functional MRI (fMRI) measurement has been shown to benefit the study of neural dynamics and functional interaction. However, acceleration of rodent brain fMRI using parallel and simultaneous multi-slice imaging techniques is hampered by the lack of high-density phased-array coils for the small brain. To overcome this limitation, we adapted phase-offset multiplanar and blipped-controlled aliasing echo planar imaging (EPI) to enable simultaneous multi-slice fMRI of the mouse brain using a single loop coil on a 9.4T scanner. Four slice bands of 0.3 × 0.3 × 0.5 mm resolution can be simultaneously acquired to cover the whole brain at a temporal resolution of 300 ms or the whole cerebrum in 150 ms. Instead of losing signal-to-noise ratio (SNR), both spatial and temporal SNR can be increased due to the increased k-space sampling compared to a standard single-band EPI. Task fMRI using a visual stimulation shows close to 80% increase of z-score and 4 times increase of activated area in the visual cortex using the multiband EPI due to the highly increased temporal samples. Resting-state fMRI shows reliable detection of bilateral connectivity by both single-band and multiband EPI, but no significant difference was found. Without the need of a dedicated hardware, we have demonstrated a practical method that can enable unparallelly fast whole-brain fMRI for preclinical studies. This technique can be used to increase sensitivity, distinguish transient response or acquire high spatiotemporal resolution fMRI.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.neuroimage.2019.03.045DOI Listing

Publication Analysis

Top Keywords

simultaneous multi-slice
12
rodent brain
8
spatial temporal
8
multiband epi
8
fmri
7
brain
5
epi
5
ultrafast fmri
4
fmri rodent
4
brain simultaneous
4

Similar Publications

Objectives: To compare integrated slice-specific dynamic shimming (iShim) and simultaneous multi-slice (SMS) readout-segmented echo-planar imaging (RESOLVE) for diffusion-weighted imaging (DWI) of malignant head and neck tumours.

Methods: In this prospective study, 45 patients with malignant head and neck lesions underwent iShim- and SMS-RESOLVE imaging with two b-values (0, 800 s/mm2) at 3 T. Subjective image quality scores (lesion distortion, signal loss, fat saturation, and artefacts), quantitative lesion distortion, quantitative image quality [signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and SNR efficiency], ADC values, and total acquisition times of iShim- and SMS-RESOLVE imaging were evaluated and compared.

View Article and Find Full Text PDF

Free-Breathing Ungated Radial Simultaneous Multi-Slice Cardiac T1 Mapping.

J Magn Reson Imaging

December 2024

Utah Center for Advanced Imaging Research (UCAIR), Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, USA.

Background: Modified Look-Locker imaging (MOLLI) T1 mapping sequences are acquired during breath-holding and require ECG gating with consistent R-R intervals, which is problematic for patients with atrial fibrillation (AF). Consequently, there is a need for a free-breathing and ungated framework for cardiac T1 mapping.

Purpose: To develop and evaluate a free-breathing ungated radial simultaneous multi-slice (SMS) cardiac T1 mapping (FURST) framework.

View Article and Find Full Text PDF

A Clinical Case of Three-Dimensional Electrical Impedance Tomography (3D-EIT) Measurements.

Cureus

November 2024

Department of Joint Research in Advanced Medicine for Electromagnetic Engineering, Shimane University, Izumo, JPN.

Article Synopsis
  • Electrical impedance tomography (EIT) is a non-invasive imaging technique that captures the bioelectrical impedance of the chest wall and has recently evolved to produce 3D images rather than just single-plane views.
  • A new prototype of a multi-slice EIT system was tested on a 62-year-old female patient with severe pneumonia, showcasing its ability to generate detailed 3D images that closely matched traditional CT scans.
  • The study revealed an unusual airflow pattern in pneumonia patients, where air entered the upper lung regions first, differing from healthy individuals, highlighting the system’s potential for better understanding lung function in disease contexts.
View Article and Find Full Text PDF

Simultaneous multi-slice cardiac real-time MRI at 0.55T.

Magn Reson Med

November 2024

Ming Hsieh Department of Electrical and Computer Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California, USA.

Purpose: To determine the feasibility of simultaneous multi-slice (SMS) real-time MRI (RT-MRI) at 0.55T for the evaluation of cardiac function.

Methods: Cardiac CINE MRI is routinely used to evaluate left-ventricular (LV) function.

View Article and Find Full Text PDF
Article Synopsis
  • Simultaneous multi-slice (multiband) acceleration in fMRI is popular but can introduce new signal artifacts, notably a shared signal across slices in both resting-state and task-based data.
  • The study introduces a correction technique called MARSS (Multiband Artifact Regression in Simultaneous Slices), which effectively detects and reduces this shared signal and helps improve data quality.
  • MARSS not only boosts signal-to-noise ratios and reduces artifacts in neuroimaging data, but also influences important statistical analyses, making it a recommended tool for researchers using multiband fMRI with moderate or high acceleration factors.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!