This paper describes the development of a miniaturized 15-MHz side-looking phased-array transducer catheter. The array features a 2-2 linear composite with 64 piezoelectric elements mechanically diced into a piece of PMN-30%PT single crystal and separated by non-conductive epoxy kerfs at a 50-μm pitch, yielding a total active aperture of 3.2 mm in the azimuth direction and 1.8 mm in the elevation direction, with an elevation natural focal depth of 8.1 mm. The array includes non-conductive epoxy backing and two front matching layers. A custom flexible circuit connects the array piezoelectric elements to a bundle of 64 individual 48-AWG micro-coaxial cables enclosed within a 1.5-m long 10F catheter. Performance characterization was evaluated via finite element analysis simulations and afterwards compared against obtained measurement results, which showed an average center frequency of 17.7 MHz, an average bandwidth of 52.2% at -6 dB, and crosstalk less than -30 dB. Imaging of a tungsten fine-wire phantom resulted in axial and lateral spatial resolutions of approximately 90 μm and 420 ìm, respectively. The imaging capability was further evaluated with colorectal tissue-mimicking phantoms, demonstrating the potential suitability of the proposed phased-array transducer for the intraoperative assessment of surgical margins during minimally invasive colorectal surgery procedures.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TUFFC.2019.2906134DOI Listing

Publication Analysis

Top Keywords

phased-array transducer
12
miniaturized 15-mhz
8
15-mhz side-looking
8
side-looking phased-array
8
transducer catheter
8
piezoelectric elements
8
non-conductive epoxy
8
direction elevation
8
fabrication characterization
4
characterization miniaturized
4

Similar Publications

Background: Preclinical studies have demonstrated that therapeutic ultrasound (TUS) increases perfusion in peripheral artery disease (PAD). This pilot study assessed the safety and effectiveness of a noninvasive TUS device in patients with advanced PAD.

Methods: A phased array of TUS transducers was fabricated on a wearable sleeve, designed to sonicate the posterior and anterior tibial arteries (and their collaterals) at the calf level.

View Article and Find Full Text PDF

Lamb wave imaging via dual-frequency fusion for grating lobe effect compensation.

Ultrasonics

February 2025

School of Information Science and Technology, Fudan University, Shanghai 200433, China.

In Lamb wave imaging based on a phased array, higher frequencies narrowband excitation pulses enable more precise damage detection and localization. However, due to the size constraints of individual transducer elements, the spacing between array elements may exceed half the wavelength of the excitation signal. This can lead to a grating lobe effect.

View Article and Find Full Text PDF

This study investigates the pulse compression technique to improve the performance of magneto-acousto-electrical tomography (MAET) with magnetic field measurements through numerical studies. Emphasizing the effects of specific coil configuration on MAET measurements, the study conducts evaluations using a linear phased array (LPA) transducer and numerical breast models with tumor inclusion. It provides feasibility and a detailed comparative analysis of various excitations, including linear frequency modulated (LFM), Barker code, and Golay code excitations in MAET.

View Article and Find Full Text PDF

Fundamental Study of Phased Array Ultrasonic Cavitation Abrasive Flow Polishing Titanium Alloy Tubes.

Materials (Basel)

October 2024

Shenzhen KiSONICS Technology Co., Ltd., Shenzhen 518107, China.

Article Synopsis
  • A new machining method using ultrasonic cavitation abrasive flow combined with phase control technology was developed to enhance the efficiency of machining the inner walls of TC4 titanium alloy tubes.
  • The study established a model for the material removal rate based on ultrasonic phase control and conducted simulations using COMSOL software to determine optimal transducer conditions, identifying a frequency of 21 kHz and spacing of 100 mm as most effective.
  • Experimental results demonstrated that polishing efficiency peaked within the first 30 minutes and stabilized after 60 minutes, confirming that voltage control contributes to consistent material removal and improved surface quality.
View Article and Find Full Text PDF

Introduction: Stroke is one of the most devastating complications of sickle cell disease (SCD). Transcranial Doppler Imaging (TCDI) is the least invasive screening method to predict patients at risk for developing stroke in the disease. After a 10-year follow-up, we longitudinally assessed the TCDI in children with SCD without neurological symptoms.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!