The aortic and pulmonary allograft heart valves (AHV) are used in the cardiac surgery for replacing the impaired semilunar valves. They are harvested from donor hearts and cryostored in tissue banks. The expiration period was set to 5 years arbitrarily. We hypothesized that their mechanical and structural properties do not deteriorate after this period. A total of 64 human AHV (31 aortic and 33 pulmonary) of different length of cryopreservation (fresh, 0-5, 5-10, over 10 years) were sampled to different tissue strips (artery, leaflet, ventriculo-arterial junction) and tested by tensile test with loading velocity 10 mm/min until tissue rupture. Neighbouring regions of tissue were processed histologically and evaluated for elastin and collagen area fraction. The results were evaluated statistically. In aortic AHV, the physical deformation response of wall samples to stress did not changed significantly neither during the process of cryopreservation nor during the first 10 years of storage. In pulmonary AHV, the ultimate strain dropped after 5 years of cryopreservation indicating that pulmonary artery was significantly less deformable at the time of rupture. On the other hand, the ultimate stress was equal during the first 10 years of cryostorage. The changes in collagen and elastin amount in the tissue samples were not associated with mechanical impairment. Neither elasticity, stiffness and solidity nor morphology of aortic and pulmonary AHV did not change reasonably with cryopreservation and in the first 10 years of cryostorage. This evidence suggests that the expiration period might be extended in the future.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10561-019-09762-xDOI Listing

Publication Analysis

Top Keywords

aortic pulmonary
16
mechanical structural
8
structural properties
8
expiration period
8
cryopreservation 10 years
8
pulmonary ahv
8
10 years cryostorage
8
pulmonary
6
aortic
5
10 years
5

Similar Publications

This case report presents the use of intravascular lithotripsy (IVL) in a 68-year-old woman with disabling bilateral claudication owing to a heavily calcified subocclusive stenosis of the infrarenal aorta. The patient had a history of tobacco use, dyslipidemia, and chronic obstructive pulmonary disease, with absent femoral pulses and severe arterial calcification. A 12-mm Shockwave L6 lithotripsy catheter was employed to treat the aortic lesion, resulting in a significant decrease in the aortic pressure gradient without the need for stenting.

View Article and Find Full Text PDF

Case report: Multisystemic smooth muscle dysfunction syndrome: a rare genetic cause of infantile interstitial lung disease.

Front Pharmacol

January 2025

Respiratory Department II, National Clinical Research Center for Respiratory Diseases, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, China.

Multisystemic smooth muscle dysfunction syndrome (MSMDS) is an autosomal dominant disorder caused by mutations in the gene, resulting in variable clinical manifestation and multi-organ dysfunction. Interstitial lung disease (ILD) is a rare phenotype of this condition. We describe a rare infant case of an 8-month-old boy who presented with progressively worsening dyspnea, along with intermittent episodes of respiratory distress and cyanosis since birth.

View Article and Find Full Text PDF

Aims: To assess the reproducibility of 4D-Flow cardiac magnetic resonance (CMR) parameters in the descending thoracic aorta-DTAo-(regurgitant fraction [RF], end-diastolic reverse flow [EDRF], and holodiastolic flow reversal [HDR]), and the relationship with RF in the sinotubular junction (STJ), and the left ventricular end-diastolic volume index (LVEDVI) in patients with chronic aortic regurgitation (AR).

Methods And Results: A descriptive study of these variables was conducted. A receiver operating characteristic curve was used to determine the optimal cut-off point.

View Article and Find Full Text PDF

Objectives: This study assessed the association between chronic obstructive pulmonary disease (COPD) severity and postoperative mortality among patients undergoing thoracic endovascular aortic repair (TEVAR) and complex endovascular aortic repair (CEVAR).

Methods: A retrospective review of the Vascular Quality Initiative database identified elective TEVAR and CEVAR cases from 2013-2022 with endograft proximal landing zone ≥2 for thoracic or complex abdominal aortic disease. Symptomatic disease, ruptures, and urgent/emergent surgeries were excluded.

View Article and Find Full Text PDF

Objective: Frailty has become an increasingly recognized perioperative risk stratification tool. While frailty has been strongly correlated with worsening surgical outcomes, the individual determinants of frailty have rarely been investigated in the setting of aortic disease. The aim of this study was to examine the determinants of an 11-factor modified frailty index (mFI-11) on mortality and postoperative complications in patients undergoing endovascular aortic aneurysm repair (EVAR).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!