Objective: Various techniques are available for stereotactic implantation of depth electrodes for intracranial epilepsy monitoring. The goal of this study was to evaluate the accuracy and effectiveness of frameless MRI-guided depth electrode implantation.
Methods: Using a frameless MRI-guided stereotactic approach (Stealth), depth electrodes were implanted in patients via burr holes or craniotomy, mostly into the medial temporal lobe. In all cases in which it was possible, postoperative MR images were coregistered to planning MR images containing the marked targets for quantitative analysis of intended versus actual location of each electrode tip. In the subset of MR images done with sufficient resolution, qualitative assessment of anatomical accuracy was performed. Finally, the effectiveness of implanted electrodes for identifying seizure onset was retrospectively examined.
Results: Sixty-eight patients underwent frameless implantation of 413 depth electrodes (96% to mesial temporal structures) via burr holes by one surgeon at 2 institutions. In 36 patients (203 electrodes) planning and postoperative MR images were available for quantitative analysis; an additional 8 procedures with 19 electrodes implanted via craniotomy for grid were also available for quantitative analysis. The median distance between intended target and actual tip location was 5.19 mm (mean 6.19 ± 4.13 mm, range < 2 mm-29.4 mm). Inaccuracy for transtemporal depths was greater along the electrode (i.e., deep), and posterior, whereas electrodes inserted via an occipital entry deviated radially. Failure to localize seizure onset did not result from implantation inaccuracy, although 2 of 62 patients (3.2%)-both with electrodes inserted occipitally-required reoperation. Complications were mostly transient, but resulted in long-term deficit in 2 of 68 patients (3%).
Conclusions: Despite modest accuracy, frameless depth electrode implantation was sufficient for seizure localization in the medial temporal lobe when using the orthogonal approach, but may not be adequate for occipital trajectories.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3171/2018.12.JNS18749 | DOI Listing |
J Colloid Interface Sci
January 2025
Department of Physics, Malaviya National Institute of Technology Jaipur, Rajasthan 302017 India. Electronic address:
Designing advanced materials that effectively mitigate the poor cycle life of battery-type electrodes with high specific capacities is crucial for next-generation energy storage systems. Herein, graphene oxide-ceria (GO-CeO) nanocomposite synthesized via a facile wet chemical route is explored as cathode for high-performance supercapacitors. The morphological analysis suggests fine ceria (CeO) nanoparticles dispersed over ultrathin graphene oxide (GO) sheets while structural studies reveal face-centered cubic phase of CeO in the nanocomposite.
View Article and Find Full Text PDFJ Colloid Interface Sci
April 2025
State Key Laboratory of Chemical Resource Engineering, College of Chemistry, Beijing University of Chemical Technology, Beijing 100029 China. Electronic address:
The design and screening of low cost and high efficiency oxygen reduction reaction (ORR) electrocatalysts is vital in the realms of fuel cells and metal-air batteries. Existing studies largely rely on the calculation of absorption free energy, a method established 20 years ago by Jens K. Nørskov.
View Article and Find Full Text PDFAngew Chem Int Ed Engl
January 2025
Shandong University, School of Chemistry and Chemical Engineering, Shanda South road 27#, 250100, Jinan, CHINA.
The poor reversibility of the zinc anode caused by interfacial side reactions and dendritic growth poses significant constraints on the practical application of aqueous zinc-ion batteries. Herein, a co-solute, acesulfame potassium, with strongly polar, zincophilic guest anions is introduced into a conventional low-concentration aqueous electrolyte. This regulation enhances the electrolyte's ionic conductivity and accelerates the desolvation process of zinc ions at the electrode/electrolyte interface.
View Article and Find Full Text PDFEur Arch Otorhinolaryngol
January 2025
Vrije Universiteit Brussel, Brussels Health Centre, Brussels, Belgium.
Purpose: Cochlear implants (CI) are the most successful bioprosthesis in medicine probably due to the tonotopic anatomy of the auditory pathway and of course the brain plasticity. Correct placement of the CI arrays, respecting the inner ear anatomy are therefore important. The ideal trajectory to insert a cochlear implant array is defined by an entrance through the round window membrane and continues as long as possible parallel to the basal turn of the cochlea.
View Article and Find Full Text PDFJ Neural Eng
January 2025
Electrical and Computer Engineering Department, New York University, 370 Jay Street, Brooklyn, New York, New York, 10012-1126, UNITED STATES.
This study investigates speech decoding from neural signals captured by intracranial electrodes. Most prior works can only work with electrodes on a 2D grid (i.e.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!