Severity: Warning
Message: file_get_contents(https://...@remsenmedia.com&api_key=81853a771c3a3a2c6b2553a65bc33b056f08&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Fiber-based organic electrochemical transistors (FECTs) provide a new platform for the realization of an ultrafast and ultrasensitive biosensor, especially for the wearable dopamine (DA)-monitoring device. Here, we presented a fully filament-integrated fabric, it exhibited remarkable mechanical compatibility with the human body, and the minimum sensing unit was an organic electrochemical transistor (OECT) based on PVA- co-PE nanofibers (NFs) and polypyrrole (PPy) nanofiber network. The introduction of NFs notably increased the specific surface area and hydrophilicity of the PA6 filament, resulting in the formation of a large area of intertwined PPy nanofiber network. The electrical performance of PPy nanofiber network-modified fibers improved considerably. For the common FECTs, the typical on/off ratio was up to two orders of magnitude, and the temporal recovery time between on and off states was shortened to 0.34 s. Meanwhile, the device exhibited continuous cycling stability. In addition, the performances of FECT-based dopamine sensors depending on different gate electrodes have also been investigated. The PPy/NFs/PA6 filament-based dopamine sensor was more superior to the gold and platinum (Pt) wires, and the sensor presented long-term sensitivity with a detection region from 1 nM to 1 μM, rapid response time to a set of DA concentrations, remarkable selectivity in the presence of sodium chloride, uric acid, ascorbic acid and glucose, and superior reproducibility. Moreover, it could also be woven into the fabric product. The novel and wearable FECT device shows the potential to become the state-of-the-art DA-monitoring platform.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acsami.9b00115 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!