Introduction: Proximal oesophageal stent deployment continues to provide challenges due to the proximity of the upper oesophageal sphincter and the associated subsequent complications such as globus sensation and stent migration. Patients with cervical oesophageal cancer have previously had limited stenting options available to them with a paucity of the literature describing the radiological technique for successfully placing these high-risk stents. In this paper, we present our experience using the Taewoong Niti-S CERVICAL Oesophageal Stent.
Materials And Methods: We describe our method for stent deployment highlighting the importance of pre-procedural planning in ensuring an adequate proximal landing zone for the short proximal flare of the stent. Furthermore, we outline how we have adapted our placement technique to incorporate a routine pre-dilatation stage which has optimised retrieval of the proximal to distal deployment system.
Results: We have placed eight cervical oesophageal stents within our institution. Contrast swallows in all the patients following stent deployment have demonstrated free flow of contrast to the stomach with all patients reporting symptomatic relief and no foreign body/globus sensation. There has been one episode of stent migration but no incidence of oesophageal perforation or haemorrhage.
Discussion: Evolution of stenting technique and the properties of the stents themselves are improving accuracy of stent placement in relation to the important landmark of the upper oesophageal sphincter.
Conclusion: Stenting of cervical oesophageal malignancy has proved successful in our institution and provided symptom relief for a subset of palliative patients who were previously unable to benefit from oesophageal stenting.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00270-019-02201-0 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!