Electrospinning has been used widely for drug delivery applications due to its versatility and ease of modification of spun fiber properties. Net drug loading and release is typically limited by the inherent surface-area of the sample. In a relatively novel approach, sintering of electrospun fiber was used to create a capsule favoring long-term delivery. We showed that electrospun polycaprolactone (PCL) retained its initial morphology out to 1042 days of in vitro exposure, illustrating its potential for extended performance. Sintering decreased the electrospun pore size by 10- and 28-fold following 56 and 57 °C exposures, respectively. At 58 and 59 °C, the PCL capsules lost all apparent surface porosity, but entrapped pores were observed in the 58 °C cross-section. The use of Rhodamine B (RhB, 479.02 g mol), Rose Bengal (RB, 1017.64 g mol) and albumin-fluorescein isothiocyanate conjugate from bovine serum (BSA-FITC, ~66,000 g mol) as model compounds demonstrated that release (RhB > RB ≫ BSA-FITC) is controlled both by molecular weight and available porosity. Interestingly, the ranking of release following sintering was 57 > 56 > 59 > 58 °C; COMSOL simulations explored the effects of capsule wall thickness and porosity on release rate. It was hypothesized that model drug adsorption on the available fiber surface-area (57 versus 56 °C) and entrapped porosity (59 versus 58 °C) could have also attributed to the observed ranking of release rates. While the 56 and 57 °C exposures allowed the bulk of the release to occur in <1 day, the capsules sintered at 58 and 59 °C exhibited release that continued after 12 days of exposure.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.msec.2019.01.095 | DOI Listing |
Bioengineering (Basel)
November 2024
Institute of Tissue Regeneration Engineering, Dankook University, Cheonan 31116, Republic of Korea.
Silk and polycaprolactone (PCL), derived from natural and synthetic sources, respectively, are suture materials commonly used in surgery. Beyond their application in sutures, they are also compelling subjects in regenerative medicine and tissue engineering. This study evaluated the effects of degummed silk microfibers compared to electrospun PCL microfibers of a similar diameter on chondrocyte behavior.
View Article and Find Full Text PDFJ Biomater Appl
January 2025
Biomedical Engineering Department, Amirkabir University of Technology (Tehran Polytechnic), Tehran, Iran.
This study aims to investigate the effects of adding nano-hydroxyapatite (nHA) to electrospun polycaprolactone (PCL) membranes for use in dental root regeneration. Porous membranes containing varying amounts of nHA (0, 1, 1.5, and 2.
View Article and Find Full Text PDFJ Biomed Mater Res B Appl Biomater
January 2025
Department of Biomedical Engineering, TOBB Economy and Technology University, Ankara, Türkiye.
Despite the variety of proposed solutions, anastomotic leakage is still a critical complication after colorectal surgery, which causes increased clinical mortality and morbidity. By enhancing microcirculation in the colonic mucosa, the use of Iloprost (Ilo) has shown promising results for the healing of anastomosis. The purpose of this study is to examine the performance of Ilo-impregnated Polycaprolactone:Gelatin electrospun membranes (PCL/Gel/Ilo) on anastomosis repair and intra-abdominal adhesion behavior in the Rat colon.
View Article and Find Full Text PDFBiosens Bioelectron
March 2025
Nanobiointeractions&Nanodiagnostics, Istituto Italiano di Tecnologia (IIT), Via Morego, 30, 16163, Genova, Italy. Electronic address:
Lateral flow assays (LFA) are widely adopted in point-of-care diagnostics across a spectrum of applications, due to their simplicity of use and cost-effectiveness. However, in complex biological matrices (e.g.
View Article and Find Full Text PDFJ Nanobiotechnology
December 2024
State Key Laboratory of Organic-Inorganic Composites, Beijing Laboratory of Biomedical Materials, Beijing University of Chemical Technology, Beijing, 100029, China.
Background: Electrospun nanofiber scaffolds have been widely used in tissue engineering because they can mimic extracellular matrix-like structures and offer advantages including high porosity, large specific surface area, and customizable structure. In this study, we prepared scaffolds composed of aligned and random electrospun polycaprolactone (PCL) nanofibers capable of delivering basic fibroblast growth factor (bFGF) in a sustained manner for repairing damaged tendons.
Results: Aligned and random PCL fiber scaffolds containing bFGF-loaded bovine serum albumin (BSA) nanoparticles (BSA-bFGF NPs, diameter 146 ± 32 nm) were fabricated, respectively.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!