A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Common and specific gait patterns in people with varying anatomical levels of lower limb amputation and different prosthetic components. | LitMetric

The present study's aim was to identify the kinematic and kinetic gait patterns and to measure the energy consumption in people with amputation according to both the anatomical level of amputation and the type of prosthetic components in comparison with a control group matched for the gait speed. Fifteen subjects with unilateral transtibial amputation (TTA), forty with unilateral transfemoral amputation (TFA) (9 with mechanical, 17 with CLeg and 14 with Genium prosthesis) and forty healthy subjects were recruited. We computed the time-distance gait parameters; the range of angular motion (RoM) at hip, knee and ankle joints, and at the trunk and pelvis; the values of the 2 peaks of vertical force curve; the full width at half maximum (FWHM) and center of activity (CoA) of vertical force; the mechanical behavior in terms of energy recovery (R-step) and energy consumption. The main results were: i) both TTA and TFA show a common gait pattern characterized by a symmetric increase of step length, step width, double support duration, pelvic obliquity, trunk lateral bending and trunk rotation RoMs compared to control groups. They show also an asymmetric increase of stance duration and of Peak1 in non-amputated side and a decrease of ankle RoM in amputated side; ii) only TFA show a specific gait pattern, depending on the level of amputation, characterized by a symmetric reduction of R-step and an asymmetric decrease of stance duration, CoA and FWHM and an increase of Peak1 in the amputated side and of hip and knee RoM, CoA and FWHM in the non-amputated side; iii) people with amputation with Genium prosthesis show a longer step length and increased hip and knee RoMs compared to people with amputation with mechanical prosthesis who conversely show an increased pelvic obliquity: these are specific gait patterns depending of the type of prosthesis. In conclusion, we identified both common and specific gait patterns in people with amputation, either regardless of, or according to their level of amputation and the type of prosthetic component.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.humov.2019.03.008DOI Listing

Publication Analysis

Top Keywords

specific gait
16
gait patterns
16
people amputation
16
level amputation
12
hip knee
12
amputation
10
common specific
8
gait
8
patterns people
8
prosthetic components
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!