Background: Blood bank inventories must balance adequate supply with minimal outdate rates. The day-to-day practice of ordering red blood cell (RBC) inventory usually involves manually comparing current inventory levels with predetermined thresholds calculated from historical usage and ordering the difference. To date, there have been no published methods for ordering RBC inventory based on laboratory characteristics of admitted patients.

Study Design And Methods: We designed and implemented a blood ordering algorithm to provide a more accurate measure of predicted RBC utilization in our institution. Cerner Command Language (Cerner Millennium) was used to extract and combine historical RBC unit usage, current inventory levels, and system-wide hematology values and blood groups. This report contains a suggested order based on current inventory, historical inventory data, ABO group, and the current "anemia index" for the institution.

Results: The mean daily total RBC inventory was significantly reduced after implementation (401.7 units vs. 309.0 units, p < 0.05). There was a significant reduction in monthly RBC outdates in this period (19.1 vs. 8.1, p < 0.05). The age of RBCs at time of transfusion was reduced as well.

Conclusion: We developed a novel algorithm that automatically generates a suggested RBC inventory order using real-time hospital-wide survey of patient ABO typing, hematology values, and historical data. After implementation of the algorithm we demonstrated a significant reduction in daily inventory levels and RBC outdate rates.

Download full-text PDF

Source
http://dx.doi.org/10.1111/trf.15272DOI Listing

Publication Analysis

Top Keywords

rbc inventory
12
current inventory
12
red blood
8
blood cell
8
inventory
8
inventory levels
8
blood
5
rbc
5
successful implementation
4
implementation automated
4

Similar Publications

Purpose: To evaluate the color match and stability of single-shade resin-based composites (RBCs) in Class V restorations before and after ultra-violet light artificial aging.

Methods: Acrylic resin teeth of A1 and A3 were randomly assigned into seven groups to be restored with single-shade RBCs and universal-shade RBCs, shades A1 and A3. Standardized Class V cavities were restored using RBC and underwent accelerated aging for 480 hours.

View Article and Find Full Text PDF

Introduction: Periprosthetic joint infections (PJIs) occur at a rate of 1-2% in primary arthroplasties and 4% in revisions, posing a significant healthcare challenge. PJI diagnosis is hindered by absence of a universally accepted diagnostic standard. The primary outcome was to develop a predictive model to identify patients at risk of developing unforeseen PJI subsequent to presumed aseptic revision of total hip arthroplasty (THA).

View Article and Find Full Text PDF

Background: Blood product constraints have increased the focus on inventory management as blood banks have faced challenges that impact supply chains and donor availability. Solutions often include a reduction in transfusion volumes through multidisciplinary improvements, but this is often coupled with a reduction in blood bank inventory to match reduced demand. We sought to improve inventory availability within the blood bank without modification of transfusion rates through solutions that prevented unnecessary RBC orders and crossmatching.

View Article and Find Full Text PDF

One-step on-chip preparation of nanoparticle-conjugated red blood cell carriers.

Colloids Surf B Biointerfaces

February 2025

State Key Laboratory of Precision Measuring Technology & Instruments, and College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China. Electronic address:

Red blood cell (RBC)-based carriers have emerged as promising vehicles for drug delivery due to their inherent biocompatibility and biodegradability. Traditional methods for loading nanoparticles (NPs) onto RBC surfaces often involve labor-intensive processes like incubation and multiple centrifugation steps, limiting their practicality and controllability. In this study, we introduce a fully integrated acoustofluidic platform that enables one-step preparation of NP-loaded RBC carriers with controlled modification and on-site purification.

View Article and Find Full Text PDF

Objective: The aim of this study is to evaluate the efficacy and safety of oxidized regenerated cellulose (ORC) in patients who underwent coronary artery bypass grafting (CABG) surgery and to compare the results of patients in whom ORC was used or not used for control of bleeding.

Method: Pre-, intra-, and post-operative demographic and medical parameters of the patients in whom ORC was used or not used were compared. Quantitative data were analyzed with mean and standard deviation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!