This is a single-institution retrospective study of closed suction drain outputs in primary three-piece IPP cases performed between 2014 and 2017 by a single surgeon. The aim was to investigate the impact of closed suction drains (CSD) during penile prosthesis placement. One hundred and sixty-nine patients underwent intraoperative placement of a closed suction drain. Drain outputs were measured at 12 and 24 h, and postoperative complications were documented. There were no hematomas or infections observed within the patient cohort. The drain output decreased significantly between the first and subsequent 12 h period. Surgical time was associated with statistically significant increases in CSD output at 12 and 24 h with a near linear relationship between surgical times and CSD at 12 and 24 h. Penile prosthesis placement in patients on aspirin did not affect the CSD output volume. Closed suction drains should be considered in all patients undergoing placement of inflatable penile prosthesis, particularly in those cases with longer operative time.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1038/s41443-019-0130-2 | DOI Listing |
J Pediatr Urol
January 2025
Department of Pediatric Urology, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milano, Italy. Electronic address:
Introduction: Bladder stones (BS) in children are a rare condition and represent 1-5 % of all urinary tract stones. With advances in miniaturized endoscopes and intracorporeal lithotripters, percutaneous cystolithotomy has been demonstrated to be an effective, safe and quick technique, despite the longer operative time. This limitation may be overcome by a semi-closed-circuit vacuum-assisted technology (vamPCL), characterized by a continuous inflow and a suction-controlled outflow (ClearPetra®).
View Article and Find Full Text PDFSci Rep
January 2025
Department of Orthopedics, Shanghai Changzheng Hospital, Naval Medical University, 415 Fengyang Road, Huangpu District, Shanghai, 200003, People's Republic of China.
The necessity of routinely placing closed suction wound drainage in spinal surgery has been questioned. This study aims to assess if closed suction wound drainage is necessary for posterior atlantoaxial fixation via intermuscular approach. The functional outcomes of these 40 patients who underwent posterior atlantoaxial fixation via intermuscular approach without drainage tube (Group A) were compared with that of a control group, which consisted of 68 randomly enrolled cases with posterior atlantoaxial fixation via intermuscular approach with drainage tube (Group B).
View Article and Find Full Text PDFBiomimetics (Basel)
December 2024
Department of Aeronautics and Astronautics, National Cheng Kung University, Tainan 701, Taiwan.
In this study, a fish scale structure with low viscous drag was proposed and applied to the suction surface of a compressor cascade to reduce total pressure loss and suppress corner separation, a key source of compressor inefficiency. By using CFD simulations, the biomimetic structure was identified and integrated into the cascade design. To evaluate its effects, we analyzed secondary flow structures using 2D projected streamlines, axial velocity density (AVD), and vortex visualization techniques.
View Article and Find Full Text PDFFront Pediatr
December 2024
Department of PICU (or Pediatric Research Institute), Children's Hospital of Chongqing Medical University, Chongqing, China.
Deep sternal wound infection (DSWI) is a rare but potentially devastating complication of median sternotomy performed in cardiac surgery. This report summarizes the nursing management of two pediatric cases with a DSWI treated using Do It Yourself (DIY) negative pressure suction (DIY-NPS) after surgery. The technique maintains a continuous suction pressure of 75 mmHg and intermittently flushes small volumes of fluid to stimulate granulation tissue formation and control systemic infection.
View Article and Find Full Text PDFACS Appl Mater Interfaces
January 2025
Centre for MicroElectroMechanical Systems (CMEMS), University of Minho, Azurem Campus, 4800-058 Guimaraes, Portugal.
The World Health Organization (WHO) reports 684,000 deaths/year due to slips and falls (SFs), with ∼38 million people requiring medical attention per annum. In particular, SFs on ice surfaces account for 45% of all SF incidents, costing over $100 billion globally in healthcare, intensive care, and insurance expenses. Current antislip solutions focus on hydrophobicity to repel interfacial fluids, aiming to maintain solid-to-solid contact.