Connected drug delivery devices are increasingly being developed to support patient supervision and counseling in home setting. Features may include dosing reminders, adherence trackers, tools for patient education, and patient diaries to collect patient-reported outcomes, as well as monitoring tools with interfaces between patients and health care professionals (HCPs). Five connected devices have been selected as the basis for a review of the clinical evidence concerning the impact of electronic tools on treatment adherence and efficacy outcomes. Disease areas covered include multiple sclerosis, diabetes, hypertension, liver and renal transplant recipients, tuberculosis, hepatitis C, clinically isolated syndrome, asthma, and COPD. From studies comparing the use of electronic feedback tools to standard of care, there is an initial evidence for a higher adherence to treatment and better outcomes among patients who use the electronic tools. To substantiate the assumption that connected devices can improve adherence in an outpatient setting over a prolonged period of time, further data from controlled randomized studies are required. Key barriers to the broader adoption of connected devices include data privacy laws that may prevent data sharing with HCPs in some countries, as well as the need to demonstrate that the tools are consistently used and generate a high-quality and reproducible database. If these challenges can be addressed in a way that is agreeable to all stakeholders, it is expected that the future value of connected devices will be to 1) facilitate and improve patient involvement in disease management in a flexible care setting, 2) enable early treatment decisions, and 3) complement value-based reimbursement models.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6419593 | PMC |
http://dx.doi.org/10.2147/MDER.S198943 | DOI Listing |
Int J Surg
December 2024
Department of Advanced Robotic and Endoscopic Surgery, Fujita Health University, Aichi, Japan.
Background: Telesurgery has been made increasingly possible with the advancements in robotic surgical platforms and network connectivity. However, long-distance transnational complex robotic surgeries such as gastrectomy have yet to be attempted.
Methods: Multiple transnational network connections by Science Innovation Network (SINET), Japan Gigabit Network (JGN), and Arterial Research and Education Network in Asia-Pacific (ARENA-PAC) were established and tested by multiple surgeons in a dry box model.
Nat Commun
January 2025
School of Chemistry and Physics, ARC Research Hub in Zero-emission Power Generation for Carbon Neutrality, and Centre for Materials Science, Queensland University of Technology, Brisbane, QLD, Australia.
Here, we design exotic interfaces within a flexible thermoelectric device, incorporating a polyimide substrate, Ti contact layer, Cu electrode, Ti barrier layer, and thermoelectric thin film. The device features 162 pairs of thin-film legs with high room-temperature performance, using p-BiSbTe and n-BiTeSe, with figure-of-merit values of 1.39 and 1.
View Article and Find Full Text PDFPLoS One
January 2025
School of Resources and Environment, Inner Mongolia University of Technology, Hohhot, China.
The aim of this study is to address the limitations of convolutional networks in recognizing modulation patterns. These networks are unable to utilize temporal information effectively for feature extraction and modulation pattern recognition, resulting in inefficient modulation pattern recognition. To address this issue, a signal modulation recognition method based on a two-way interactive temporal attention network algorithm has been developed.
View Article and Find Full Text PDFHardwareX
March 2025
INRAE - French National Research Institute for Agriculture, Food and Environment, REVERSAAL Research Unit, 5 rue de la Doua, CS 20244, 69625 Villeurbanne Cedex, France.
Sensors play an important role in both the continuous monitoring and intermittent analyses, which are essential for the study of wastewater treatment plant management and conducting related research. Given the significant environmental impact of the issues involved, accurate measurement of the volume of water flowing into and out of treatment plants is a key parameter for plant management, ecotoxicological studies and academic research programs. Traditionally, flow measurements have been based on calibrated weirs or venturi flumes, using water level measurements for conversion into flow, according to established relationships.
View Article and Find Full Text PDFHeliyon
January 2025
Gas Company of Hormozgan Province, National Iranian Gas Company, Hormozgan, Iran.
The absence of a mercaptan compounds analyzer in natural gas pressure reduction stations (PRS) odorizer leads to inaccuracies in the injection dosage, often resulting in quantities beyond standard limits and consequently increasing odorant consumption. Insufficient odorant levels in natural gas can pose safety risks to consumers, as the gas may become odorless at the end of the pipeline. Therefore, accurate determination of the concentration of key odorant compounds in natural gas can reduce both costs and environmental risks.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!