Background: Prostate cancer (PCa) is the second leading cause of cancer death in men. Several articles have reported that microRNA-21 (miR-21) and microRNA-30c (miR-30c) have diagnostic values for PCa, but the results are inconclusive. In order to precisely assess the diagnostic values of miR-21 and miR-30c for PCa, this meta-analysis is performed.

Methods: Articles were searched in the databases of PubMed, Embase, and Web of Knowledge (search date: September 6, 2018). Studies were included if they were designed to evaluate the diagnostic performance of miR-21 or miR-30c for PCa. Using Stata 12.0 and Meta-Disc 1.4, the pooled sensitivity (SEN), specificity (SPE), positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and area under curve (AUC) of the summary receiver-operating characteristic (SROC) curve with the corresponding 95% CI were calculated.

Results: Overall, ten studies (six studies for miR-21 and four for miR-30c) involving1,371 participants were included in this meta-analysis. For miR-21, the pooled SEN and SPE were, respectively, 0.91 (95% CI: 0.87-0.94) and 0.88 (95% CI: 0.82-0.93), the pooled PLR and NLR were, respectively, 7.74 (95% CI: 4.81-12.47), 0.1 (95% CI: 0.06-0.15), the DOR was 77.64 (95% CI: 34.64-174.02), AUC of SROC was 0.95 (95% CI: 0.93-0.97). For miR-30c, the pooled SEN and SPE were, respectively, 0.74 (95% CI: 0.65-0.81) and 0.78 (95% CI: 0.72-0.83), the pooled PLR and NLR were, respectively, 3.39 (95% CI: 2.69-4.26), and 0.34 (95% CI: 0.26-0.44), the DOR was 10.06 (95% CI: 6.96-14.55), and AUC of SROC was 0.83 (95% CI: 0.79-0.86).

Conclusion: For PCa, miR-21 is a good diagnostic biomarker and miR-30c is a moderate diagnostic biomarker.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6411321PMC
http://dx.doi.org/10.2147/CMAR.S189026DOI Listing

Publication Analysis

Top Keywords

95%
13
mir-21 mir-30c
12
prostate cancer
8
diagnostic values
8
mir-30c pca
8
likelihood ratio
8
pooled sen
8
sen spe
8
pooled plr
8
plr nlr
8

Similar Publications

Article Synopsis
  • The study measured fibrinogen fluorescence at temperatures between 20 and 80 degrees Celsius across different pH levels.
  • It was found that raising the temperature from 20 to 40 degrees Celsius did not change the structure of fibrinogen in solutions with pH between 4.5 and 9.3.
  • However, temperatures between 40 to 50 degrees Celsius caused some structural changes in neutral solutions, and temperatures above 50-55 degrees Celsius led to significant denaturation of the fibrinogen molecule.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!