Clinical observations suggest that tinnitus may interfere with programming cochlear implants (CIs), the process of optimizing the transmission of acoustic information to support speech perception with a CI. Despite tinnitus being highly prevalent among CI users, its effects and impact on CI programming are obscure. This study characterized the nature, time-course, and impact of tinnitus effects encountered by audiologists and patients during programming appointments. Semistructured interviews with six CI audiologists were analyzed thematically to identify tinnitus effects on programming and related coping strategies. Cross-sectional surveys with 67 adult CI patients with tinnitus and 20 CI audiologists in the United Kingdom examined the prevalence and time-course of those effects. Programming parameters established at CI activation appointments of 10 patients with tinnitus were compared with those of 10 patients without tinnitus. On average, 80% of audiologists and 45% of patients reported that tinnitus makes measurements of threshold (T) levels more difficult because patients confuse their tinnitus with CI stimulation. Difficulties appeared most common at CI activation appointments, at which T levels were significantly higher in patients with tinnitus. On average, 26% of patients reported being afraid of "loud" CI stimulation worsening tinnitus, affecting measurements of loudest comfortable (C) stimulation levels, and 34% of audiologists reported observing similar effects. Patients and audiologists reported that tinnitus makes programming appointments more difficult and tiresome for patients. The findings suggest that specific programming strategies may be needed during CI programming with tinnitus, but further research is required to assess the potential impact on outcomes including speech perception.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6423681 | PMC |
http://dx.doi.org/10.1177/2331216519836624 | DOI Listing |
Artif Intell Med
December 2024
Knowledge Management & Discovery Lab, Otto-von-Guericke-University Magdeburg, Germany. Electronic address:
Background: Current clinical decision support systems (DSS) are trained and validated on observational data from the clinic in which the DSS is going to be applied. This is problematic for treatments that have already been validated in a randomized clinical trial (RCT), but have not yet been introduced in any clinic. In this work, we report on a method for training and validating the DSS core before introduction to a clinic, using the RCT data themselves.
View Article and Find Full Text PDFBr J Pain
January 2025
Department of Pain Medicine and Neuromodulation, The Walton centre NHS foundation Trust, Liverpool, UK.
Although spinal cord stimulator (SCS) therapy is generally used safely to treat chronic neuropathic pain conditions, this document highlights the less reported complication of unusual neurological problems including headaches. These developed temporally after the initiation of SCS therapy despite initial positive response to pain. The mechanisms might include activation of trigeminal receptors and neuroplasticity after SCS.
View Article and Find Full Text PDFEar Hear
December 2024
Sensorineural Pathology Programme, Centro de Investigación Biomédica en Red en Enfermedades Raras, CIBERER, Madrid, Spain.
Objectives: To estimate the prevalence of tinnitus and hyperacusis in patients with vestibular migraine (VM), and to define the association with hearing loss, anxiety, and depression.
Design: A cross-sectional, multicenter study including 51 adult patients with definite or probable VM, defined according to the Barany Society diagnostic criteria. Audiological examinations were performed by pure tones extended to high frequencies to assess hearing thresholds.
Biomedicines
December 2024
Department of Pharmacology and Pharmacotherapy, Faculty of Medicine, University of Debrecen, Nagyerdei St. 98, H-4032 Debrecen, Hungary.
Over the past few decades, many studies have been conducted to explore the link between tinnitus and lipid metabolism, yielding inconsistent results. In our current study, we compared the prevalence of various lipid metabolism abnormalities in patients with chronic subjective idiopathic tinnitus (CSIT) to the official prevalence data of dyslipidaemia in the general adult Hungarian population. To counteract the distorting effect of the co-increase in both conditions with age, we also examined this relationship by age groups.
View Article and Find Full Text PDFAntioxidants (Basel)
December 2024
Institute of Pharmacology and Toxicology, Paracelsus Medical University, 5020 Salzburg, Austria.
Cisplatin is an established component of treatment protocols for various solid malignancies but carries a significant potential for serious adverse effects. Ototoxicity from cisplatin treatment is an important dose-limiting toxicity that manifests as bilateral, progressive, irreversible, dose-dependent sensorineural hearing loss, ear pain, tinnitus, and vestibular dysfunction. Despite the recent approval of sodium thiosulphate for the prevention of cisplatin-induced hearing loss (CIHL) in pediatric patients, structured prevention programs are not routinely implemented in most hospitals, and reducing platinum-induced ototoxicity in adults remains an important clinical problem without established treatment options.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!