Finite element (FE) method has been widely used to study the screw-bone connections. Screw threads are often excluded from the FE spine model to reduce computational cost. However, no study has been conducted to compare the effect of such simplification in the screw models on the predicting accuracy of the model. The effects of different screw-bone connection types on the overall spine biomechanics are also unknown. In this study, three different types of screw-bone connections were compared using FE simulations in this study: (1) screw and bone are not fully bonded (contact connection); (2) screw is rigidly bonded with the bone (bonded connection); and (3) simplified-geometry-rigid (SGR) connection. Screw pullout test and physiological spinal loading test were simulated for the screws in this study: (1) pullout test where the pedicle screws were inserted in polyurethane foam; and (2) physiological spinal loading test (flexion, extension, lateral bending, and axial rotation) where the screws were fused into previously-validated FE lumbar spine model. The FE spine model used in this study included L-L spine levels and simulated major ligaments and resultant muscle forces. This study indicated that the holding capability in the screw-bone interaction is smaller and the bone and implants are subjected to larger von Mises stress (up to 44.88%) in the contact connection than those in the bonded connection. Among the four spinal loading cases tested in this study, flexion produced the highest von Mises stress in both the bone and the implants. Considerable differences were observed between simplified and non-simplified screw FE models in the von Mises stress at screw-bone contact region within spinal loading environment and the ultimate screw pullout strength in pullout test. This study concluded that both the spinal implants and the bone are subjected to higher stress immediately after the pedicle-screw-instrumented surgery and before the screw and bone are fully bonded. The screw-bone interface is less likely to fail after the screw and bone are fully bonded. SGR screw model is able to predict screw force and rod stress that are consistent with those predicted by non-simplified screw models.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.medengphy.2019.03.004DOI Listing

Publication Analysis

Top Keywords

pullout test
16
spinal loading
16
physiological spinal
12
screw
12
spine model
12
screw models
12
screw bone
12
bone fully
12
fully bonded
12
von mises
12

Similar Publications

Purpose: This study aimed to compare the biomechanical properties of four meniscal suture configurations-two simple sutures (TSS), two cinch sutures, a locking loop stitch (LLS), and a delta-grip stitch (DGS)-for transtibial pullout repair of medial meniscus posterior root tears (MMPRTs) using porcine menisci.

Methods: Forty porcine menisci were randomly assigned to each suture configuration with all-inside repair. All specimens were subjected to cyclic loading for 1000 cycles, followed by a load-to-failure test.

View Article and Find Full Text PDF

Asphalt pavement, widely utilized in transportation infrastructure due to its favourable properties, faces significant degradation from chloride salt erosion in coastal areas and winter deicing regions. In this study, two commonly used asphalt binders, 70# base asphalt and SBS (Styrene-Butadiene-Styrene)-modified asphalt, were utilized to study the chloride salt erosion effect on asphalt pavement by immersing materials in laboratory-prepared chloride salt solutions. The conventional properties and adhesion of asphalt were assessed using penetration, softening point, ductility, and pull-off tests, while Fourier transform infrared spectroscopy (FTIR) elucidated the erosion mechanism.

View Article and Find Full Text PDF

Objective: Combining oblique lumbar interbody fusion (OLIF) with posterior pedicle screw fixation (PPSF) has been proposed to reduce cage subsidence, especially in osteoporotic spines. Recently, anterolateral screw-rod fixation has gained interest as it allows direct pathology observation and avoids a posterior approach. However, controversies exist between anterolateral screw fixation systems and traditional PPSF due to variations in osteoporotic vertebral mineral density, screw fixation positions, and fixation methods (bicortical vs.

View Article and Find Full Text PDF

Background: The fracture of an endodontic instrument within the root canal system can occur during root canal therapy, complicating thorough cleaning and shaping. Consequently, managing the broken fragment becomes crucial.

Methods: Eighty Nickel-titanium (NiTi) #20 K-files (Mani, Tochigi, Japan) were cut 8 mm from the tip, fixed into a corkboard, and classified into five groups (n = 14 each).

View Article and Find Full Text PDF

The new type of support disc-type anchor is an expanded body anchor with broad application prospects, and its load-bearing performance is significantly better than that of traditional anchors. However, there is a problem of premature shear damage in traditional support disc-type anchors. In order to solve this problem, this paper improves the traditional support disk anchor.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!