Objective: Lumbar interbody spacers are widely used in lumbar spinal fusion. The goal of this study is to analyze the biomechanics of a lumbar interbody spacer (Clydesdale Spinal System, Medtronic Sofamor Danek, Memphis, Tennessee, USA) inserted via oblique lumbar interbody fusion (OLIF) or direct lateral interbody fusion (DLIF) approaches, with and without posterior cortical screw and rod (CSR) or pedicle screw and rod (PSR) instrumentation.

Methods: Lumbar human cadaveric specimens (L2-L5) underwent nondestructive flexibility testing in intact and instrumented conditions at L3-L4, including OLIF or DLIF, with and without CSR or PSR.

Results: OLIF alone significantly reduced range of motion (ROM) in flexion-extension (P = 0.005) but not during lateral bending or axial rotation (P ≥ 0.63). OLIF alone reduced laxity in the lax zone (LZ) during flexion-extension (P < 0.001) but did not affect the LZ during lateral bending or axial rotation (P ≥ 0.14). The stiff zone (SZ) was unaffected in all directions (P ≥ 0.88). OLIF plus posterior instrumentation (cortical, pedicle, or hybrid) reduced the mean ROM in all directions of loading but only significantly so with PSR during lateral bending (P = 0.004), without affecting the compressive stiffness (P > 0.20). The compressive stiffness with the OLIF device without any posterior instrumentation did not differ from that of the intact condition (P = 0.97). In terms of ROM, LZ, or SZ, there were no differences between OLIF and DLIF as standalone devices or OLIF and DLIF with posterior instrumentation (CSR or PSR) (P > 0.5).

Conclusions: OLIF alone significantly reduced mobility during flexion-extension while maintaining axial compressive stiffness compared with the intact condition. Adding posterior instrumentation to the interbody spacer increased the construct stability significantly, regardless of cage insertion trajectory or screw type.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.wneu.2019.02.200DOI Listing

Publication Analysis

Top Keywords

posterior instrumentation
16
lumbar interbody
12
olif dlif
12
olif reduced
12
lateral bending
12
compressive stiffness
12
olif
9
oblique lumbar
8
interbody spacer
8
interbody fusion
8

Similar Publications

Purpose: Asymmetric anterior closing-wedge high tibial osteotomy (ACWHTO) allows correction of both excessive posterior tibial slope (PTS) and varus deformity. However, the complexity of this surgery requires a high degree of accuracy, which is less likely to be achieved with standard instrumentations. This study aimed to determine the accuracy of 3D patient-specific cutting guides (PSCGs) to provide the accurate planned correction in the frontal and sagittal planes.

View Article and Find Full Text PDF

Over the past two decades, both suture and sutureless techniques for scleral fixation of intraocular lenses have seen significant advancement, driven by improvements in methodologies and instrumentation. Despite numerous reports demonstrating the effectiveness, safety, and superiority of these techniques, each approach carries with it its own drawbacks, including an elevated risk of certain postoperative complications. This article delves into various surgical techniques for scleral fixation of posterior chamber intraocular lenses, discussing their procedural nuances, benefits, drawbacks, postoperative complications, and outcomes.

View Article and Find Full Text PDF

Fully Navigated Single-Position Prone Lateral Lumbar Interbody Fusion: A Detailed Technical Report and Description of 15 Cases.

Int J Spine Surg

December 2024

Spine Team, Division of Orthopedic Surgery and Musculoskeletal Trauma Care, Geneva University Hospitals, Faculty of Medecine, University of Geneva, Geneva, Switzerland

Background: Navigation increases the precision and safety of pedicle screw placement and has been used to place interbody cages for lateral lumbar interbody fusion. Single-position surgery shortens its duration and that of anesthesia. The aim of this study was the feasibility of simultaneous cage and screw placement in a single prone position using intraoperative navigation without the need for additional fluoroscopy and a detailed technical description of this procedure.

View Article and Find Full Text PDF

Objectives: To evaluate whether unilateral functional posterior crossbite in growing children creates an asymmetry in masseter muscle thickness and whether this asymmetry is normalized after crossbite correction.

Materials And Methods: Two groups of growing individuals were studied prospectively: (i) a treatment group: children with unilateral functional posterior crossbite, undergoing crossbite correction with maxillary expansion; and (ii) a control group: children without transversal malocclusions and orthodontic treatment. The thickness of the masseter muscles was measured bilaterally using ultrasonographic recordings at three time points: pre-treatment (T0); 9 months after (T1); and 30 months after posterior crossbite correction (T2); and at equivalent time points in the control group.

View Article and Find Full Text PDF

Biomechanical study of two different fixation methods for the treatment of Neer III proximal humerus fractures.

BMC Musculoskelet Disord

December 2024

Department of Orthopedic Surgery, Shanghai Sixth People's Hospital, Shanghai Jiao Tong University School of Medicine, Jinshan Branch, Jinshan District Central Hospital, Shanghai, 201500, China.

Background: The lateral locking plate for the proximal humerus is currently the most commonly used surgical procedure for the treatment of elderly proximal humeral comminuted fractures. Previous studies have found that the rate of postoperative complications in patients of proximal humerus fractures with medial column involvement is relatively high. Through biomechanical methods, this study aims to investigate the effectiveness of the conventional lateral locking plate fixation along with the addition of the metacarpal supporting plate on the medial column in the treatment for proximal humeral fractures involving the medial column.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!