In a randomized clinical study, contraceptive efficacy and bleeding patterns were studied in a group of healthy, regularly menstruating, non-lactating women (n = 84) using two 4.4 cm covered silastic rods containing levonorgestrel, Norplant(R)-2, and compared with another group of women (n = 88) using six 3.4 cm capsules also containing levonorgestrel, Norplant(R). The silastic rods or capsules were placed subdermally in the medial aspect of the upper arm. No method failure was reported up to 24 months of use in this study with either of the device. The bleeding pattern was also similar for both devices as indicated by average episode length, number of bleeding runs and number of spotting days. The continuation rates with both devices were over 80 per 100 users at the end of 12 months and over 65 per 100 users at the end of 24 months. Discontinuations due to expulsion of the device, bleeding problems or personal reasons were few and similar for both devices. The results suggest that silastic-covered rods, Norplant(R)-2, which are comparatively easier to insert and remove and have similar clinical effect, could replace capsules, Norplant(R), as a long-term reversible subdermal contraceptive.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0010-7824(86)90016-8DOI Listing

Publication Analysis

Top Keywords

silastic rods
8
device bleeding
8
100 users
8
users months
8
phase randomized
4
randomized comparative
4
comparative clinical
4
clinical trial
4
trial norplant
4
capsules
4

Similar Publications

Levonorgestrel-releasing silastic implants are a form of subdermal contraception that utilizes implanted silastic rods to release levonorgestrel, providing long-acting reversible contraception over an extended period of time. This case report presents a female who had lost a significant amount of weight after receiving levonorgestrel-releasing implants 25 years prior. During the elapsed period, the rods were palpable and uncomfortable.

View Article and Find Full Text PDF

A new analytical method for the determination of naproxen, ketoprofen, diclofenac, carbamazepine, and triclosan (TCS) in water samples by liquid chromatography is developed and validated. The method is based on the extraction of the analytes by a polydimethylsiloxane (PDMS) rod. The different parameters affecting extraction, such as the addition of salt, pH, initial volume, extraction and elution times and elution solvent, as well as the application of sonication, are studied.

View Article and Find Full Text PDF

Development of polydimethylsiloxane-microdiamond composite materials for application as sorptive devices.

J Chromatogr A

February 2020

Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania, 7001, Australia; ARC Training Centre for Portable Analytical Separation Technologies (ASTech), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania, 7001, Australia. Electronic address:

The development and application of non-porous and porous sorptive rods, comprised of polydimethylsiloxane-microdiamond (PDMS-MD) composites, is reported. The PDMS-MD composites were made porous using inorganic salt (NaCl and NaHCO) particles as dissolvable templates. Materials with pore size of ~40 µm down to ~5 µm were produced.

View Article and Find Full Text PDF

Guided bone regeneration (GBR) scaffolds are futile in many clinical applications due to infection problems. In this work, we fabricated GBR with an anti-infective scaffold by ornamenting 2D single crystalline bismuth-doped nanohydroxyapatite (Bi-nHA) rods onto segmented polyurethane (SPU). Bi-nHA with high aspect ratio was prepared without any templates.

View Article and Find Full Text PDF

Simple, precise, and low-cost methods for the simultaneous determination of phenolic endocrine disrupting compounds such as bisphenol A, trichlorophenol, pentachlorophenol, 4-nonylphenol, and 4-octylphenol in water samples were developed. The Direct, in situ derivatization methods are based on polydimethylsiloxane rod extraction followed by liquid desorption and chromatographic analysis by liquid chromatography and diode array detection. Several parameters affecting the extraction and desorption of the phenolic compounds and their acetylated derivates were studied, as well as the chromatographic and detection conditions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!