A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

MMP-8-Responsive Polyethylene Glycol Hydrogel for Intraoral Drug Delivery. | LitMetric

MMP-8-Responsive Polyethylene Glycol Hydrogel for Intraoral Drug Delivery.

J Dent Res

1 The State Key Laboratory Breeding Base of Basic Science of Stomatology (Hubei-MOST) and Key Laboratory for Oral Biomedical Ministry of Education, School and Hospital of Stomatology, Wuhan University, Wuhan, China.

Published: May 2019

Currently available drug delivery systems for oral diseases suffer from short retention time and poor local concentrations at the target site. A biodegradable stimulus-responsive hydrogel was synthesized in the present study to evaluate its application as an environmentally sensitive carrier for on-demand intraoral drug delivery. The hydrogel was synthesized from diacrylate-containing polyethylene glycol-based scaffolds and a cysteine-terminated peptide crosslinker (CGPQG↓IWGQC) via a Michael-type addition reaction. Because CGPQG↓IWGQC can be cleaved by matrix metalloproteinase 8 (MMP-8), minocycline hydrochloride, bovine serum albumin, or an antibacterial peptide (KSL) was incorporated into the scaffolds to evaluate the MMP-8-responsive release behavior of the on-demand drug delivery system. Hydrogel characterization and gelation kinetics were examined with gel time, Fourier-transform infrared spectroscopy, scanning electron microscopy, and measurements of rheologic parameters. Degradation behavior and MMP-8-responsive drug release were performed by high-performance liquid chromatography and protein-specific assay. Biocompatibility evaluation indicated that the hydrogels were noncytotoxic. Antibacterial testing demonstrated that the released drugs were able to maintain bioactivity. Taken together, these results suggest that the MMP-8-sensitive hydrogel is a promising candidate for on-demand intraoral localized drug delivery. Because MMP-8 is one of the most important biomarkers for periodontitis, the MMP-8-responsive hydrogel has potential to be used for in situ adaptive degradation in response to chronic periodontitis and peri-implantitis. This notion has to be tested in animal models of periodontal disease.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0022034519831931DOI Listing

Publication Analysis

Top Keywords

drug delivery
20
intraoral drug
8
hydrogel synthesized
8
on-demand intraoral
8
hydrogel
6
drug
6
delivery
5
mmp-8-responsive
4
mmp-8-responsive polyethylene
4
polyethylene glycol
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!